Behavior of a fast counting system with an avalanche photodiode detector for synchrotron X-rays

被引:23
作者
Kishimoto, S
机构
[1] Photon Factory, Inst. of Materials Structure Science, Tsukuba, Ibaraki 305
关键词
synchrotron radiation; avalanche photodiode; count rate; dead time; multi-bunch mode;
D O I
10.1016/S0168-9002(97)00816-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The behavior of a fast counting system with an avalanche photodiode (APD) detector was examined using X-rays produced by synchrotron radiation. The system with the APD detector had a dead time of about 4 ns. This provided superior performance with a count-rate capability of up to 10(8) counts/s in a multi-bunch mode of a storage ring. The relation between the input photon rates and the observed count rates is given based on a model for pulsed X-rays. The model well explains the behavior of a system with the APD detector in a single-bunch mode and at input rates below 10(8) photons/s in a multi-bunch mode. However, at higher rates the shape and variable amplitude of the pulse from an amplifier cause a difference from the behavior predicted by the model.
引用
收藏
页码:343 / 353
页数:11
相关论文
共 12 条
[1]   COUNTING LOSSES OF DETECTORS FOR X-RAYS FROM STORAGE-RINGS [J].
ARNDT, UW .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1978, 11 (07) :671-673
[2]   HIGH-BRILLIANCE BEAMLINE AT THE EUROPEAN SYNCHROTRON-RADIATION FACILITY [J].
BOSECKE, P ;
DIAT, O ;
RASMUSSEN, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1636-1638
[3]   DEAD-TIME LOSSES WITH PULSED BEAMS [J].
CORMACK, AM .
NUCLEAR INSTRUMENTS & METHODS, 1962, 15 (03) :268-272
[4]   PILE-UP PHENOMENA IN SOLID-STATE DETECTION EFFECTS DUE TO SYNCHROTRON SOURCES [J].
COUSINS, CSG ;
GERWARD, L ;
LAUNDY, D ;
MEADS, RE ;
OLSEN, JS ;
SHELDON, BJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 324 (03) :598-608
[5]   HIGH TIME RESOLUTION X-RAY MEASUREMENTS WITH AN AVALANCHE PHOTODIODE DETECTOR [J].
KISHIMOTO, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :824-827
[6]   RECENT DEVELOPMENTS IN THE AVALANCHE PHOTODIODE X-RAY-DETECTOR FOR TIMING AND FAST COUNTING MEASUREMENTS [J].
KISHIMOTO, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :2314-2316
[7]  
Knoll G. F., 1989, RAD DETECTION MEASUR, P120
[8]   COUNTING STATISTICS AND LOSS CORRECTIONS FOR THE APS [J].
LEE, WK ;
MILLS, DM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1225-1228
[9]  
Matsumoto Y., COMMUNICATION
[10]   HORIZONTAL-TYPE 4-CIRCLE DIFFRACTOMETER STATION OF THE VERTICAL WIGGLER BEAMLINE AT THE PHOTON FACTORY [J].
SATOW, Y ;
IITAKA, Y .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :2390-2393