Verification of "lateral secondary ion mass spectrometry" as a method for measuring lateral dopant dose distributions in microelectronics test structures

被引:5
作者
von Criegern, R
Jahnel, F
Lange-Gieseler, R
Pearson, P
Hobler, G
Simionescu, A
机构
[1] Siemens AG, Corp Technol, D-81730 Munich, Germany
[2] GEC Marconi Ltd, Towcester NN12 8EQ, Northants, England
[3] Vienna Tech Univ, Inst Solid State Elect, A-1040 Vienna, Austria
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B | 1998年 / 16卷 / 01期
关键词
D O I
10.1116/1.589816
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Lateral secondary ion mass spectrometry (SIMS) has been demonstrated to be capable, within certain limits, of measuring the lateral straggle and diffusion of dopants under mask edges. In the present work measurements of lateral dose distributions of arsenic and boron in silicon are presented and discussed, and information on the error margins of the method derived. It is shown that the lateral dose distribution of arsenic and boron can be measured down to dose levels of 5 x 10(12) cm(-2) and 2.6 x 10(13) cm(-2), respectively. In repeated measurements, the profile shapes have been reproduced to within a few nanometers, and the profile position relative to the mask edge determined with about +/-10 nm error, It is this rather high degree of accuracy that allows Lateral SIMS data to be of value in the calibration and validation of two-dimensional process simulators. An example is given showing the correlation between IMSIL (Technical University Vienna) simulation and experimental data for an as-implanted sample. By comparing experimental data from samples after dopant diffusion and at several topography variants with TMA SUPREM4 simulation, it is shown that an accurate determination of the topography of the implant window in the vicinity of the mask edge is an essential prerequisite of any simulator calibration. (C) 1998 American Vacuum Society.
引用
收藏
页码:386 / 393
页数:8
相关论文
共 3 条
[1]   MONTE-CARLO SIMULATION OF ION-IMPLANTATION INTO TWO-DIMENSIONAL AND 3-DIMENSIONAL STRUCTURES [J].
HOBLER, G ;
SELBERHERR, S .
IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 1989, 8 (05) :450-459
[2]   METHOD FOR THE MEASUREMENT OF THE LATERAL DOSE DISTRIBUTION OF DOPANTS AT IMPLANTATION OR DIFFUSION MASK EDGES (LATERAL SIMS) [J].
VONCRIEGERN, R ;
JAHNEL, F ;
BIANCO, M ;
LANGEGIESELER, R .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1994, 12 (01) :234-242
[3]  
VONCRIEGERN R, 1997, P 10 INT C 2 ION MAS, V10, P299