Peroxidase-based amperometric sensor of hydrogen peroxide generated in oxidase reaction: Application to creatinine and creatine assay

被引:37
作者
Kinoshita, H [1 ]
Torimura, M
Kano, K
Ikeda, T
机构
[1] Kwassui Womens Coll, Nagasaki 850, Japan
[2] Kyoto Univ, Grad Sch Agr, Div Appl Life Sci, Sakyo Ku, Kyoto 60601, Japan
关键词
biosensor; hydrogen peroxide; creatinine; creatine; peroxidase; sarcosine oxidase; creatine amidinohydrolase; creatinine amidohydrolase;
D O I
10.1002/elan.1140091603
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Peroxidase (POD) was entrapped on a ferrocene (Fc)-embedded carbon paste (CP) electrode with a dialysis membrane to construct a POD-Fc-CP electrode for the reductive amperometric determination of hydrogen peroxide (H2O2). The electrode allowed the H2O2 detection down to 10 nM (under stirring), with a linear relation up to 15 mu M, and without change of the response over one month. On the other hand, a plastic-formed carbon (PFC) electrode can donate electrons to POD without any specific mediator. The POD-entrapped PFC electrode produced a relative current density of 24 % compared with the POD-Fc-CP electrode. The reductive detection of H2O2 with the POD-Fc-CP electrode was applied to the determination of creatinine and creatine in serum and urine using sarcosine oxidase, creatine amidinohydrolase, and creatinine amidohydrolase as the reagents. The significance of the membrane-covered POD-Fc-CP electrode in the coupling of the oxidase reaction is also discussed.
引用
收藏
页码:1234 / 1238
页数:5
相关论文
共 28 条
[2]   FERRICINIUM ION AS AN ELECTRON-ACCEPTOR FOR OXIDO-REDUCTASES [J].
CASS, AEG ;
DAVIS, G ;
GREEN, MJ ;
HILL, HAO .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 190 (1-2) :117-127
[3]   ELECTRON-TRANSFER KINETICS AT MODIFIED CARBON ELECTRODE SURFACES - THE ROLE OF SPECIFIC SURFACE SITES [J].
CHEN, PH ;
FRYLING, MA ;
MCCREERY, RL .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3115-3122
[4]   CARBON-FIBERS AS ELECTRODE MATERIALS FOR THE CONSTRUCTION OF PEROXIDASE-MODIFIED AMPEROMETRIC BIOSENSORS [J].
CSOREGI, E ;
GORTON, L ;
MARKOVARGA, G .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :59-70
[5]   PEROXIDASE-MODIFIED CARBON-FIBER MICROELECTRODES IN FLOW-THROUGH DETECTION OF HYDROGEN-PEROXIDE AND ORGANIC PEROXIDES [J].
CSOREGI, E ;
GORTON, L ;
MARKOVARGA, G ;
TUDOS, AJ ;
KOK, WT .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3604-3610
[6]  
Folin O, 1914, J BIOL CHEM, V17, P475
[7]  
Folin O., 1904, Z. Physiol. Chem, V41, P223
[8]   A METHOD FOR ESTIMATION OF HYDROGEN-PEROXIDE BASED ON MEDIATED ELECTRON-TRANSFER REACTIONS OF PEROXIDASES AT ELECTRODES [J].
FREW, JE ;
HARMER, MA ;
HILL, HAO ;
LIBOR, SI .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 201 (01) :1-10
[9]   AMPEROMETRIC SENSORS FOR PEROXIDE, CHOLINE, AND ACETYLCHOLINE BASED ON ELECTRON-TRANSFER BETWEEN HORSERADISH-PEROXIDASE AND A REDOX POLYMER [J].
GARGUILO, MG ;
HUYNH, N ;
PROCTOR, A ;
MICHAEL, AC .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :523-528
[10]   AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE [J].
GORTON, L ;
JONSSONPETTERSSON, G ;
CSOREGI, E ;
JOHANSSON, K ;
DOMINGUEZ, E ;
MARKOVARGA, G .
ANALYST, 1992, 117 (08) :1235-1241