Specific and selective biosensor for Salmonella and its detection in the environment

被引:67
作者
Olsen, EV
Pathirana, ST
Samoylov, AM
Barbaree, JM
Chin, BA
Neely, WC
Vodyanoy, V
机构
[1] Auburn Univ, Dept Anat Physiol & Pharmacol, Auburn, AL 36849 USA
[2] Auburn Univ, Mat Res & Educ Ctr, Auburn, AL 36849 USA
[3] Auburn Univ, Dept Chem, Auburn, AL 36849 USA
[4] Auburn Univ, Dept Biol Sci, Auburn, AL 36849 USA
关键词
acoustic wave device; biosensor; Langmuir-Blodgett monolayer; antibody;
D O I
10.1016/S0167-7012(03)00031-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The specific and selective detection of Salmonella typhymurium based on the use of a polyclonal antibody immobilized by the Langmuir-Blodgett method on the surface of a quartz crystal acoustic wave device was demonstrated in liquid samples. These biosensors were selective to S. typhymurium in the presence of large concentrations of Escherichia coli 0 1 57:H7. They were also specific to S. typhymurium since bacteria preincubated with free antibody produced no signal. Dark-field and electron microscopy showed that two different antibodies, polyvalent somatic 0 and flagellar H7, were immobilized on the sensor surface producing two distinct attachments of bacteria at the liquid-solid interface. The somatic 0 antibody exhibits a rigid, binding, while the flagellar H7 antibody forms a flexible connection allowing a large degree of freedom. When the attachment of bacteria was rigid and strong, the responses of the acoustic wave sensors correlated with changes in the mass of bacteria present at the liquid-solid interface. In contrast, when attachment was flexible, the sensor signals were inversely proportional to the additional mass of bound bacteria. This difference is probably determined by the interfacial viscoelasticity and by acoustic and electromagnetic coupling. The signals of environmentally aged sensors with either predominately rigid or flexible positioning of bacteria were correlated with changes in mass at the liquid-solid interface. Sensors with 0 or H type of binding could be used for analytical purposes. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:273 / 285
页数:13
相关论文
共 21 条
[1]   Modeling the responses of thickness-shear mode resonators under various loading conditions [J].
Bandey, HL ;
Martin, SJ ;
Cernosek, RW ;
Hillman, AR .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2205-2214
[2]   Piezoelectric quartz crystal biosensors [J].
Bunde, RL ;
Jarvi, EJ ;
Rosentreter, JJ .
TALANTA, 1998, 46 (06) :1223-1236
[3]   Acoustic waves and the study of biochemical macromolecules and cells at the sensor-liquid interface [J].
Cavic, BA ;
Hayward, GL ;
Thompson, M .
ANALYST, 1999, 124 (10) :1405-1420
[4]   Operation of acoustic plate mode immunosensors in complex biological media [J].
Dahint, R ;
Bender, F ;
Morhard, F .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3150-3156
[5]  
DAVIES LT, 1963, INTERFACIAL PHENOMEN
[6]   Interfacial properties of biotin conjugate-avidin complexes studied by acoustic wave sensor [J].
Ghafouri, S ;
Thompson, M .
LANGMUIR, 1999, 15 (02) :564-572
[7]   SMALL ODORANT MOLECULES AFFECT STEADY-STATE PROPERTIES OF MONOLAYERS [J].
ITO, H ;
MORTON, TH ;
VODYANOY, V .
THIN SOLID FILMS, 1989, 180 :1-13
[8]   Biosensors for detection of pathogenic bacteria [J].
Ivnitski, D ;
Abdel-Hamid, I ;
Atanasov, P ;
Wilkins, E .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (07) :599-624
[9]   Thickness shear mode resonators ("mass-sensitive devices") in bioanalysis [J].
Kaspar, M ;
Stadler, H ;
Weiss, T ;
Ziegler, C .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (6-7) :602-610
[10]   CHARACTERIZATION OF A QUARTZ CRYSTAL MICROBALANCE WITH SIMULTANEOUS MASS AND LIQUID LOADING [J].
MARTIN, SJ ;
GRANSTAFF, VE ;
FRYE, GC .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2272-2281