Colorectal neoplasms: Role of intravenous contrast-enhanced CT colonography

被引:28
作者
Sosna, J
Morrin, MM
Kruskal, JB
Farrell, RJ
Nasser, I
Raptopoulos, V
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Gastroenterol, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Pathol, Boston, MA 02215 USA
关键词
colon; CT; colon neoplasms; colonoscopy;
D O I
10.1148/radiol.2281020950
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate whether computed tomographic (CT) clonography with intravenously, administered contrast material can help predict malignant differentiation of colorectal neoplasms (greater than or equal to10 mm in diameter). MATERIALS AND METHODS: Enhancement of 29 consecutive colorectal neoplasms on pre- and postcontrast CT colonographic images was retrospectively measured: The neoplasms were subsequently resected. Enhancement was calculated by subtraction of attenuation values (in Hounsfield unit precontrast and postcontrast 45-second-delay prone CT colonographic sequences. The neoplasms were graded as follows: grade 1; adenoma; grade 2, adenoma with high-grade dysplasia; grade 3, well-differentiated adenocarcinoma grade 4, moderately differentiated adenocarcinoma; and grade 5, poorly differentiated adenocarcinoma. Correlation among size, histologic grade, and degree was made with Pearson and Spearman coefficients. The ability of enhancement to help predict adenocarcinoma (histologic grade, greater than or equal to3) was calculated. RESULTS: Histologic-CT colonographic correlation was performed in 29 neoplasms (mean diameter, 27.9,mm; range; 10-65 mm). There was no correlation between size and degree of enhancement, size and histologic grade (R = -0.17, P = .33), or histologic grade and, degree of enhancement (R = 0.23, P = .23). However, increasing enhancement was noted between grades 2 and 5. When an enhancement threshold of 40 HU was used for the diagnosis of adenocarcinoma grades 3-5), sensitivity was 92%; specificity was 20%, positive predictive and negative predictive value was 75%. CONCLUSION: The degree of contrast enhancement on a 45-second-delay CT colonographic image does not correlate with size or degree of histologic differentiation although increasing enhancement with lesser degrees of differentiation was noted. (C) RSNA, 2003.
引用
收藏
页码:152 / 156
页数:5
相关论文
共 35 条
[1]   Technical report: Spiral CT pneumocolon for suspected colonic neoplasms [J].
Amin, Z ;
Boulos, PB ;
Lees, WR .
CLINICAL RADIOLOGY, 1996, 51 (01) :56-61
[2]   ASSESSMENT OF RADIOLOGIC TESTS - CONTROL OF BIAS AND OTHER DESIGN CONSIDERATIONS [J].
BEGG, CB ;
MCNEIL, BJ .
RADIOLOGY, 1988, 167 (02) :565-569
[3]  
BOSSI P, 1995, CANCER RES, V55, P5049
[4]   CT colonography: Value of scanning in both the supine and prone positions [J].
Chen, SC ;
Lu, DSK ;
Hecht, JR ;
Kadell, BM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (03) :595-599
[5]   CT colonography with three-dimensional problem solving for detection of colonic polyps [J].
Dachman, AH ;
Kuniyoshi, JK ;
Boyle, CM ;
Samara, Y ;
Hoffmann, KR ;
Rubin, DT ;
Hanan, I .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (04) :989-995
[6]  
Edwards JT, 2001, AM J GASTROENTEROL, V96, P3009
[7]   Colorectal neoplasm detection using virtual colonoscopy: a feasibility study [J].
Fenlon, HM ;
Nunes, DP ;
Clarke, PD ;
Ferrucci, JT .
GUT, 1998, 43 (06) :806-811
[8]   A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps [J].
Fenlon, HM ;
Nunes, DP ;
Schroy, PC ;
Barish, MA ;
Clarke, PD ;
Ferrucci, JT .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (20) :1496-1503
[9]   CT colonography: Potential pitfalls and problem-solving techniques [J].
Fletcher, JG ;
Johnson, CD ;
MacCarty, RL ;
Welch, TJ ;
Reed, JE ;
Hara, AK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) :1271-1278
[10]   Optimization of CT colonography technique: Prospective trial in 180 patients [J].
Fletcher, JG ;
Johnson, CD ;
Welch, TJ ;
MacCarty, RL ;
Ahlquist, DA ;
Reed, JE ;
Harmsen, WS ;
Wilson, LA .
RADIOLOGY, 2000, 216 (03) :704-711