High-performance liquid chromatographic assay of NG-monomethyl-L-arginine, NG-dimethyl-L-arginine, and NGNG-dimethyl-L-arginine using 4-fluoro-7-nitro-2,1,3-benzoxaldiazole as a fluorescent reagent

被引:47
作者
Nonaka, S
Tsunoda, M
Imai, K
Funatsu, T
机构
[1] Univ Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, Japan
[2] Musashino Univ, Pharmaceut Sci Res Inst, Nishitokyo, Tokyo 2028585, Japan
关键词
(N; NG)-N-G-dimethyl-L-arginine; (ADMA); nitric oxide synthase; 4-fluoro-7-nitro-2,1,3-benzoxadiazole; fluorescence;
D O I
10.1016/j.chroma.2005.01.052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
N-G-Monomethyl-L-arginine (L-NMMA), N-G,N-G'-dimethyl-L-arginine (ADMA), and N-G,N-G-dimethyl-L-arginine (SDMA) are emerging cardiovascular risk factors. A high-performance liquid chromatographic method with fluorescence detection for the simultaneous determination Of L-NMMA, ADMA and SDMA is described. The assay employed 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) as a fluorescent derivatization reagent. After solid phase extraction with cation-exchange column, the methylated arginines were converted to fluorescent derivatives with NBD-F, and the derivatives were separated within 32 min on a reversed-phase column. N-w-Propyl-L-arginine was used as an internal standard. Extrapolated detection limits were 12 nM (12 fmol per injection) for L-NMMA and 20 nM (20 fmol per injection) for ADMA and SDMA, respectively, with a signal-to-noise ratio of 3. The calibration curves for L-NMMA, ADMA and SDMA were linear within the range of 50-5000 fmol. The method was applied to the quantitative determination Of L-NMMA, ADMA and SDMA in 200 mul of rat plasma. The concentrations of L-NMMA, ADMA and SDMA in rat plasma were 0.16 +/- 0.03, 0.80 +/- 0.25 and 0.40 +/- 10.21 muM, respectively (n = 5). (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 45
页数:5
相关论文
共 28 条
[1]   Plasma concentrations of asymmetric dimethylarginine are increased in patients with type 2 diabetes mellitus [J].
Abbasi, F ;
Asagmi, T ;
Cooke, JP ;
Lamendola, C ;
McLaughlin, T ;
Reaven, GM ;
Stuehlinger, M ;
Tsao, PS .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (10) :1201-+
[2]   Elevated L-arginine/dimethylarginine ratio contributes to enhanced systemic NO production by dietary L-arginine in hypercholesterolemic rabbits [J].
BodeBoger, SM ;
Boger, RH ;
Kienke, S ;
Junker, W ;
Frolich, JC .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1996, 219 (02) :598-603
[3]   Determination of asymmetrical dimethylarginine by capillary electrophoresis-laser-induced fluorescence [J].
Caussé, E ;
Siri, N ;
Arnal, JF ;
Bayle, C ;
Malatray, P ;
Valdiguié, P ;
Salvayre, R ;
Couderc, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 741 (01) :77-83
[4]   Determination of N-G,N-G-dimethylarginine in human plasma by high-performance liquid chromatography [J].
Chen, BM ;
Xia, LW ;
Zhao, RQ .
JOURNAL OF CHROMATOGRAPHY B, 1997, 692 (02) :467-471
[5]   Interference of L-arginine analogues with L-arginine transport mediated by the y+ carrier hCAT-2B [J].
Closs, EI ;
Basha, FZ ;
Habermeier, A ;
Forstermann, U .
NITRIC OXIDE-BIOLOGY AND CHEMISTRY, 1997, 1 (01) :65-73
[6]   An automated analyzer for methylated arginines in rat plasma by high-performance liquid chromatography with post-column fluorescence reaction [J].
Dobashi, Y ;
Santa, T ;
Nakagomi, K ;
Imai, K .
ANALYST, 2002, 127 (01) :54-59
[7]   RELATIVE IMPORTANCE OF KIDNEY AND LIVER IN SYNTHESIS OF ARGININE BY RAT [J].
FEATHERSTON, WR ;
ROGERS, QR ;
FREEDLAND, RA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1973, 224 (01) :127-129
[8]   Serum concentrations of asymmetric (ADMA) and symmetric (SDMA) dimethylarginine in patients with chronic kidney diseases [J].
Fleck, C ;
Schweitzer, F ;
Karge, E ;
Busch, M ;
Stein, G .
CLINICA CHIMICA ACTA, 2003, 336 (1-2) :1-12
[9]   Serum concentrations of asymmetric (ADMA) and symmetric (SDMA) dimethylarginine in renal failure patients [J].
Fleck, C ;
Janz, A ;
Schweitzer, F ;
Karge, E ;
Schwertfeger, M ;
Stein, G .
KIDNEY INTERNATIONAL, 2001, 59 :S14-S18
[10]   Rapid simultaneous determination of arginine and methylated arginines in human urine by high-performance liquid chromatography-mass spectrometry [J].
Huang, LF ;
Guo, FQ ;
Liang, YZ ;
Hu, QN ;
Cheng, BM .
ANALYTICA CHIMICA ACTA, 2003, 487 (02) :145-153