Effect of radial gradient of temperature on the performance of large-diameter high-performance liquid chromatography columns I. Analytical conditions

被引:26
作者
Dapremont, O
Cox, GB
Martin, M
Hilaireau, P
Colin, H
机构
[1] Prochrom R&D, F-54250 Champigneulles, France
[2] Ecole Super Phys & Chim Ind, Phys & Mecan Milieux Heterogenes Lab, F-75231 Paris 05, France
关键词
preparative chromatography; mathematical modelling; temperature gradients;
D O I
10.1016/S0021-9673(97)01067-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of a large-diameter chromatographic column can be drastically reduced when the solvent enters the column at a temperature different from that of the wall of the column, A radial temperature gradient inside the column will affect the physical properties of the solvent and the chromatographic behaviour of the solute resulting in a deformation of the band profile. A mathematical model is proposed to take into account the effect of a radial gradient of temperature in a large-diameter column on the chromatographic peak shape under linear conditions. The model is then compared with experimental results in preparative columns of different sizes. A good agreement between experiment and theory has been found showing a serious effect of thermal conditions on separation quality, depending on the column size, It is also demonstrated that a small difference of temperature can be helpful to compensate practical effect of frits and distribution of the sample at the extremities of the packed bed. Finally, it demonstrates the necessity to perform efficiency measurement under different thermal conditions to have a good comparison between columns. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:81 / 99
页数:19
相关论文
共 25 条
[1]   EFFECT OF RADIAL THERMAL-GRADIENTS IN ELEVATED-TEMPERATURE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ABBOTT, S ;
ACHENER, P ;
SIMPSON, R ;
KLINK, F .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :123-135
[2]  
BRANDT A, UNPUB J CHROMATOGR A
[3]  
COLIN H, 1988, HIGH PERFORMANCE LIQ, pCH11
[4]  
COLIN H, 1989, PREPARATIVE SCALE CH, pCH3
[5]   END-EFFECTS AND BAND SPREADING IN LIQUID COLUMN CHROMATOGRAPHY [J].
COQ, B ;
CRETIER, G ;
ROCCA, JL ;
KASTNER, R .
JOURNAL OF CHROMATOGRAPHY, 1979, 178 (01) :41-61
[6]  
DAPREMONT O, 1994, PREP 94
[7]  
DAPREMONT O, 1996, PREP 96
[8]   EARLY PHASES OF THE DISPERSION OF A SAMPLE INJECTED IN POISEUILLE FLOW [J].
GOLAY, MJE ;
ATWOOD, JG .
JOURNAL OF CHROMATOGRAPHY, 1979, 186 (DEC) :353-370
[9]   SAMPLING AND EXTRA-COLUMN EFFECTS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - INFLUENCE OF PEAK SKEW ON PLATE COUNT CALCULATIONS [J].
KIRKLAND, JJ ;
YAU, WW ;
STOKLOSA, HJ ;
DILKS, CH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (08) :303-316
[10]   INTERACTION OF RADIAL AND AXIAL-DISPERSION IN LIQUID-CHROMATOGRAPHY IN RELATION TO INFINITE DIAMETER EFFECT [J].
KNOX, JH ;
LAIRD, GR ;
RAVEN, PA .
JOURNAL OF CHROMATOGRAPHY, 1976, 122 (JUL7) :129-145