Fatal airway obstruction from percutaneous endoscopic gastrostomy in an infant with Pierre Robin sequence

被引:5
作者
Barak, Michal
Capdevila, Marisa
Katz, Yeshayahu
机构
[1] Technion Israel Inst Technol, Bruce Rappaport Fac Med, Dept Anesthesiol, IL-31096 Haifa, Israel
[2] HaEmek Med Ctr, Dept Anesthesiol, Afula, Israel
关键词
ABNORMALITIES;
D O I
10.1213/01.ane.0000261511.95239.3b
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
引用
收藏
页码:292 / 293
页数:2
相关论文
共 4 条
[1]
Pierre Robin sequence: Secondary respiratory difficulties and intrinsic feeding abnormalities [J].
Cruz, MJ ;
Kerschner, JE ;
Beste, DJ ;
Conley, SF .
LARYNGOSCOPE, 1999, 109 (10) :1632-1636
[2]
Nargozian C, 2004, PAEDIATR ANAESTH, V14, P53, DOI 10.1046/j.1460-9592.2003.01200.x
[3]
Scheller J G, 1991, J Clin Anesth, V3, P45, DOI 10.1016/0952-8180(91)90205-2
[4]
Successful management of a neonate with Pierre-Robin syndrome and severe upper airway obstruction by long term placement of a laryngeal mask airway [J].
Yao, CT ;
Wang, HN ;
Tai, YT ;
Tsai, TY ;
Wu, JM .
RESUSCITATION, 2004, 61 (01) :97-99