Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw

被引:118
作者
Haynes, RC [1 ]
Poll, RG [1 ]
Miles, AW [1 ]
Weston, RB [1 ]
机构
[1] Univ Bath, Sch Mech Engn, Bath BA2 7AY, Avon, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 1997年 / 28卷 / 5-6期
关键词
D O I
10.1016/S0020-1383(97)00035-1
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The most commonly reported failure mode of sliding hip screws in published literature is cut-out of the lag screw. This study investigates the resistance to failure of the femoral head, with lag screws used in two types of sliding hip screws, the gamma locking nail (Howmedica) and the dynamic hip screw (DHS) (Synthes). The investigation consisted of biomechanical tests under static loading conditions on 12 pairs of cadaveric femoral heads, to establish the failure lends due to screw cut-out for the two implant lag screws. The gamma nail appeared to reduce the tendency to cut-out in the osteoporotic bone (soft) associated with elderly patients in whom these devices are commonly used (p<0.05). In high density bone (hard) the gamma lag screw also appeared to be stronger, because the DHS showed a tendency to bend. The larger diameter of the gamma nail lag screw resists bending and appeals to reduce the risk of cut-out compared with the DHS. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:337 / 341
页数:5
相关论文
共 19 条
[1]   HEALING COMPLICATIONS AFTER INTERNAL-FIXATION OF TROCHANTERIC HIP-FRACTURES - THE PROGNOSTIC VALUE OF OSTEOPOROSIS [J].
BARRIOS, C ;
BROSTROM, LA ;
STARK, A ;
WALHEIM, G .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1993, 7 (05) :438-442
[2]   FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[3]   INTERTROCHANTERIC FEMORAL FRACTURES - MECHANICAL FAILURE AFTER INTERNAL-FIXATION [J].
DAVIS, TRC ;
SHER, JL ;
HORSMAN, A ;
SIMPSON, M ;
PORTER, BB ;
CHECKETTS, RG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :26-31
[4]  
DOHERTY JH, 1979, CLIN ORTHOP RELAT R, V141, P184
[5]   A PROSPECTIVE COMPARATIVE-STUDY OF THE COMPRESSION HIP SCREW AND THE GAMMA-NAIL [J].
GOLDHAGEN, PR ;
OCONNOR, DR ;
SCHWARZE, D ;
SCHWARTZ, E .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1994, 8 (05) :367-372
[6]  
Jacobs R.R., 1980, CLIN ORTHOP RELAT R, V146, P62
[7]   UNSTABLE TROCHANTERIC FRACTURES TREATED WITH SLIDING SCREW-PLATE SYSTEM - BIOMECHANICAL STUDY OF UNSTABLE TROCHANTERIC FRACTURES .3. [J].
JENSEN, JS ;
TONDEVOLD, E ;
MOSSING, N .
ACTA ORTHOPAEDICA SCANDINAVICA, 1978, 49 (04) :392-397
[8]  
KANE M, 1993, J ORTHOP TRAUMA, V7, P191
[9]   BIOMECHANICAL ANALYSIS OF THE SLIDING CHARACTERISTICS OF COMPRESSION HIP SCREWS [J].
KYLE, RF ;
WRIGHT, TM ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (08) :1308-1314
[10]   GAMMA-NAILS AND DYNAMIC HIP SCREWS FOR PERITROCHANTERIC FRACTURES - A RANDOMIZED PROSPECTIVE-STUDY IN ELDERLY PATIENTS [J].
LEUNG, KS ;
SO, WS ;
SHEN, WY ;
HUI, PW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :345-351