Ion selectivity of a poly(3-pentylmethoxythiophene) LB-layer modified carbon-fiber microelectrode as a consequence of the second order filtering in voltcoulometry

被引:5
作者
Gmucova, Katarina [1 ]
Weis, Martin
Barancok, Drahoslav
Cirak, Julius
Tomcik, Pavol
Pavlasek, Juraj
机构
[1] Slovak Acad Sci, Inst Phys, SK-84511 Bratislava, Slovakia
[2] Slovak Acad Sci, Inst Normal & Pathol Physiol, SK-83334 Bratislava, Slovakia
[3] Slovak Univ Technol Bratislava, Fac Elect Engn & Informat Technol, Dept Phys, SK-81219 Bratislava, Slovakia
来源
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS | 2007年 / 70卷 / 03期
关键词
Langmuir-Blodgett deposition; kinetics of redox reaction; polythiophene modified electrode; voltammetry; voltcoulometry;
D O I
10.1016/j.jbbm.2006.09.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ion selective properties of poly(3-pentylmethoxytbiophene) Langmuir-Blodgett film modified carbon-fiber microelectrode are described. The study of the electrode behavior indicates that important features occur if two electrochemical methods, one of them being kinetics sensitive, are used. While in case of the typical steady-state voltammetry the electrode remains sensitive to both the cations and anions, the kinetics-sensitive properties of voltcoulometry based on the second-order filtering scheme disable the observation of anions. As a model system a mixture of copper and dopamine ions is used. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:385 / 390
页数:6
相关论文
共 35 条
[1]  
Alt E R, 1990, Int Rev Exp Pathol, V31, P165
[2]   Dynamic electrochemistry: Methodology and application [J].
Anderson, JL ;
Coury, LA ;
Leddy, J .
ANALYTICAL CHEMISTRY, 2000, 72 (18) :4497-4520
[3]  
AOKI K, 1981, J ELECTROANAL CHEM, V122, P19, DOI 10.1016/0368-1874(81)87338-8
[4]   Surface modified microelectrodes for selective electroanalysis of metal ions in environmental components [J].
Barancok, D ;
Cirák, J ;
Tomcík, P ;
Gmucová, K .
BIOELECTROCHEMISTRY, 2002, 55 (1-2) :153-155
[5]  
Bard A. J., 2000, ELECTROCHEMICAL METH, P580
[6]   CHEMICALLY AND PHYSICALLY MODIFIED ELECTRODES - SOME NEW DEVELOPMENTS [J].
BARENDRECHT, E .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1990, 20 (02) :175-185
[7]  
Bolognesi A, 1999, ACTA POLYM, V50, P151, DOI 10.1002/(SICI)1521-4044(19990401)50:4<151::AID-APOL151>3.3.CO
[8]  
2-G
[9]  
Del Valle MA, 1998, J APPL ELECTROCHEM, V28, P943
[10]   MEASUREMENT OF BLOOD HOLOCERULOPLASMIN BY EIA USING A MOUSE MONOCLONAL-ANTIBODY DIRECTED TO HOLOCERULOPLASMIN - IMPLICATION FOR MASS-SCREENING OF WILSON DISEASE [J].
ENDO, F ;
TAKETA, K ;
NAKAMURA, K ;
AWATA, H ;
TANOUE, A ;
EDA, Y ;
MATSUDA, I .
JOURNAL OF INHERITED METABOLIC DISEASE, 1994, 17 (05) :616-620