Development of a fluoroimmunosensor for theophylline using immobilised antibody

被引:43
作者
Garcinuño, RM [1 ]
Fernández, P [1 ]
Pérez-Conde, C [1 ]
Gutiérrez, AM [1 ]
Cámara, C [1 ]
机构
[1] Univ Complutense Madrid, Fac Quim, Dept Quim Analit, E-28040 Madrid, Spain
关键词
Protein A; permanent immobilisation; fluoroimmunosensor; theophylline;
D O I
10.1016/S0039-9140(00)00435-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flowthrough theophylline fluoroimmunosensor with an antibody covalently immobilised on a solid support has been developed. The immobilisation technique proposed in this paper used protein-A on control pore glass (Protein A-CPG) in an immunoreactor and dimethylsuberimidate as a cross-linking agent. Several supports and cross-linking reagents were tested in order to obtain oriented immobilisation and thus efficiency of the immunological reaction and reusability of the immunosensor. The immunosensor performance characteristics were established. The precision expressed as RSD, was 1.6%; the detection limit was 3 mu g l(-1); the immunoreactor lifetime was established in 80 assays and there were no interferences with structurally similar compounds such as aminophylline, dihydroxypropyltheophylline and caffeine in the determination of the analyte. This fluoroimmunosensor was applied to determine theophylline in human serum samples from patients of the Puerta de Hierro Hospital in Madrid. The results obtained show that there are no significant differences between the proposed immunosensor and the high-pressure liquid chromatographic method with UV detection used by the Hospital, thus demonstrating the validity of the method. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:825 / 832
页数:8
相关论文
共 17 条
[1]   MONOCLONAL-ANTIBODIES INTO THE 90S - THE ALL-PURPOSE TOOL [J].
CARLSSON, R ;
GLAD, C ;
BORREBAECK, CKA .
BIO-TECHNOLOGY, 1989, 7 (06) :567-&
[2]  
Chan D.W., 1987, IMMUNOASSAY PRACTICA
[3]  
GIL EP, 1990, CLIN CHEM, V36, P662
[4]   Determination of theophylline in blood serum by UV spectrophotometry and partial least-squares (PLS-1) calibration [J].
Goicoechea, HC ;
Olivieri, AC ;
de la Peña, AM .
ANALYTICA CHIMICA ACTA, 1999, 384 (01) :95-103
[5]  
HERNANDO PF, 1991, J PHARM BIOMED ANAL, V9, P112
[6]  
Kizu J, 1999, BIOMED CHROMATOGR, V13, P15, DOI 10.1002/(SICI)1099-0801(199902)13:1<15::AID-BMC766>3.3.CO
[7]  
2-4
[8]  
LEE IH, 1988, MIKROCHIM ACTA, V3, P207
[9]   RAPID FLOW-INJECTION SANDWICH-TYPE IMMUNOASSAYS OF PROTEINS USING AN IMMOBILIZED ANTIBODY REACTOR AND ADENOSINE-DEAMINASE ANTIBODY CONJUGATES [J].
LEE, IH ;
MEYERHOFF, ME .
ANALYTICA CHIMICA ACTA, 1990, 229 (01) :47-55
[10]   Disposable liposome immunosensor for theophylline combining an immunochromatographic membrane and a thick-film electrode [J].
Lee, KS ;
Kim, TH ;
Shin, MC ;
Lee, WY ;
Park, JK .
ANALYTICA CHIMICA ACTA, 1999, 380 (01) :17-26