Two-stage microtrap as an injection device for continuous on-line gas chromatographic monitoring

被引:47
作者
Feng, CH [1 ]
Mitra, S [1 ]
机构
[1] New Jersey Inst Technol, Dept Chem Engn Chem & Environm Sci, Newark, NJ 07102 USA
关键词
sample preparation; air analysis; microtraps; monitoring; continuous; volatile organic compounds;
D O I
10.1016/S0021-9673(98)00041-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microtrap is a small diameter sorbent trap packed with adsorbent. In previous studies it has been used as a concentration cum injection device for on-line GC monitoring of trace level organics. The microtrap is prone to breakthrough as it contains a small quantity of adsorbent. A larger diameter trap with more adsorbent reduces breakthrough, but generates broad injection bands that reduce chromatographic resolution, in this paper, we present a two-stage microtrap system. The first, a large diameter retention trap is packed with more sorbent material to increase the breakthrough volume or time. The retention trap is desorbed and the analytes are refocused onto the smaller diameter microtrap referred to as the injection trap. A few seconds delay is provided and then the injection microtrap is desorbed to generate a sharp band injection for GC separation. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:169 / 176
页数:8
相关论文
共 14 条
[1]   SOME CRITICAL PARAMETERS IN COLLECTION, RECOVERY AND GAS-CHROMATOGRAPHIC ANALYSIS OF ORGANIC POLLUTANTS IN AMBIENT AIR USING LIGHT ADSORBENTS [J].
BERTONI, G ;
BRUNER, F ;
LIBERTI, A ;
PERRINO, C .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :263-270
[2]  
BETZ WR, 1993, SAMPLING ANAL AIRBOR
[3]   HEADSPACE GAS-ANALYSIS - QUANTITATIVE TRAPPING AND THERMAL-DESORPTION OF VOLATILES USING FUSED-SILICA OPEN TUBULAR CAPILLARY TRAPS [J].
BURGER, BV ;
MUNRO, Z .
JOURNAL OF CHROMATOGRAPHY, 1986, 370 (03) :449-464
[4]   CHROMATOGRAPHIC CHARACTERIZATION OF POROUS POLYMERS FOR USE AS ADSORBENTS IN SAMPLING COLUMNS [J].
BUTLER, LD ;
BURKE, MF .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1976, 14 (03) :117-122
[5]  
Frank H, 1995, J HIGH RES CHROMATOG, V18, P83
[6]  
LOVKVIST P, 1987, ANAL CHEM, V59, P818
[7]   Characteristics of microtrap-based injection systems for continuous monitoring of volatile organic compounds by gas chromatography [J].
Mitra, S ;
Xu, YH ;
Chen, WJ ;
Lai, A .
JOURNAL OF CHROMATOGRAPHY A, 1996, 727 (01) :111-118
[8]   HIGH-CAPACITY THERMAL-DESORPTION MODULATORS FOR GAS-CHROMATOGRAPHY [J].
MITRA, S ;
PHILLIPS, JB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1988, 26 (12) :620-623
[9]   CONTINUOUS GAS-CHROMATOGRAPHIC MONITORING OF LOW CONCENTRATION SAMPLE STREAMS USING AN ONLINE MICROTRAP [J].
MITRA, S ;
YUN, C .
JOURNAL OF CHROMATOGRAPHY, 1993, 648 (02) :415-421
[10]   A SEQUENTIAL VALVE-MICROTRAP INJECTION SYSTEM FOR CONTINUOUS, ONLINE GAS-CHROMATOGRAPHIC ANALYSIS AT TRACE LEVELS [J].
MITRA, S ;
LAI, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1995, 33 (06) :285-289