Rapid method for detection of Salmonella in milk by surface plasmon resonance (SPR)

被引:75
作者
Mazumdar, Saikat Datta
Hartmann, Markus
Kampfer, Peter
Keusgen, Michael
机构
[1] Univ Marburg, Inst Pharmaceut Chem, D-35032 Marburg, Germany
[2] Univ Giessen, Inst Angew Mikrobiol, D-35392 Giessen, Germany
关键词
surface plasmon resonance (SPR); Salmonella typhimurium; polyclonal antibody; immunoassay; plasmonic (R); milk;
D O I
10.1016/j.bios.2006.09.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The Plasmonic (R) surface plasmon resonance (SPR) device was used to develop a rapid, simple and specific immunoassay for detection of Salmonella in milk. Rapid detection of Salmonella contamination is a major challenge for the food industry. Salmonella contamination is well known in all foods including pasteurised milk. The SPR assay was developed as a sandwich model using a polyclonal antibody against Salmonella as capture and detection antibody. Milk spiked with Salmonella typhimurium cells, killed by thimerosal (1%, w/w) treatment was used. Using the Plasmonic (R) SPR assay it was possible to detect S. typhimurium down to a concentration of 1.25 x 10(5) cells ml(-1) in both milk and buffer system. The results obtained are comparable with existing, approved rapid Salmonella detection techniques. No negative effects on the sensitivity of the assay are encountered due to the milk matrix. Hence, no sample preparation or clean-up steps are required. The sample volume requirement for the assay is only 10 mu l. Using the assay S. typhimurium was detected in milk within 1 h, whereas the cultural techniques require 3-4 days for presumptive positive isolates and further time for confirmation. The rapid tests require at least 24 h for the results. The Plasmonic (R) SPR device operates on the Kretschmann configuration and is a cuvette-based system with the advantage of having eight channels on one single SPR chip. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:2040 / 2046
页数:7
相关论文
共 46 条
[1]   An outbreak of Yersinia enterocolitica O:8 infections associated with pasteurized milk [J].
Ackers, ML ;
Schoenfeld, S ;
Markman, J ;
Smith, MG ;
Nicholson, MA ;
DeWitt, W ;
Cameron, DN ;
Griffin, PM ;
Slutsker, L .
JOURNAL OF INFECTIOUS DISEASES, 2000, 181 (05) :1834-1837
[2]   Safety and efficacy of low-energy cardioversion of 500 patients using two different techniques [J].
Andraghetti, A ;
Scalese, M .
EUROPACE, 2001, 3 (01) :4-9
[3]  
ASCENZI JM, 1996, HDB DISINFECTANTS AN, P92
[4]  
Baylis CL, 2000, LETT APPL MICROBIOL, V30, P320, DOI 10.1046/j.1472-765X.2000.00724.x
[5]   EVALUATION OF THE VITEK IMMUNODIAGNOSTIC ASSAY SYSTEM (VIDAS) FOR THE DETECTION OF SALMONELLA IN FOODS [J].
BLACKBURN, CD ;
CURTIS, LM ;
HUMPHESON, L ;
PETITT, SB .
LETTERS IN APPLIED MICROBIOLOGY, 1994, 19 (01) :32-36
[6]   Immunochemical detection of Salmonella group B, D and E using an optical surface plasmon resonance biosensor [J].
Bokken, GCAM ;
Corbee, RJ ;
van Knapen, F ;
Bergwerff, AA .
FEMS MICROBIOLOGY LETTERS, 2003, 222 (01) :75-82
[7]  
EARLY R, 1995, TECHNOLOGY DAIRY PRO, P22
[8]   Implementation of real-time PCR to tetrathionate broth enrichment step of Salmonella detection in poultry [J].
Eyigor, A ;
Carli, KT ;
Unal, CB .
LETTERS IN APPLIED MICROBIOLOGY, 2002, 34 (01) :37-41
[9]   Detection of Escherichia coli O157:H7 using a surface plasmon resonance biosensor [J].
Fratamico, PM ;
Strobaugh, TP ;
Medina, MB ;
Gehring, AG .
BIOTECHNOLOGY TECHNIQUES, 1998, 12 (07) :571-576
[10]   Development of a biosensor-based immunoassay for screening of chloramphenicol residues in milk [J].
Gaudin, V ;
Maris, P .
FOOD AND AGRICULTURAL IMMUNOLOGY, 2001, 13 (02) :77-86