Controlled analysis of factors associated with insufficient sample on outpatient endometrial biopsy

被引:40
作者
Bakour, SH [1 ]
Khan, KS [1 ]
Gupta, JK [1 ]
机构
[1] Univ Birmingham, Acad Dept Obstet & Gynaecol, Birmingham Minimal Access & Surg Training MAST Ct, Birmingham B15 2TT, W Midlands, England
来源
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY | 2000年 / 107卷 / 10期
关键词
D O I
10.1111/j.1471-0528.2000.tb11627.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
We examined the relative significance of hysteroscopic and ultrasonographic evidence of endometrial atrophy in relation to insufficient sample on outpatient endometrial biopsy in women with abnormal uterine bleeding. Multivariate logistic regression modelling was used to evaluate the independent effects of age, menopausal status, hysteroscopic findings and sonographic endometrial thickness on outpatient endometrial sampling (sufficient or insufficient) used as the binary dependent variable. Insufficient sample on endometrial biopsy was associated with hysteroscopic finding of endometrial atrophy (OR 4.79, 95% CI 1.05-21.91, P = 0.04) and sonographic endometrial thickness below 5 mm (OR 0.19, 95% CI 0.07-0.53, P = 0.001). There was no association with patient's age and menopausal status. In conclusion, when reassuring women with insufficient sample on outpatient endometrial biopsy, one can be confident about absence of pathology provided the hysteroscopic and sonographic endometrial assessment is consistent with endometrial atrophy.
引用
收藏
页码:1312 / 1314
页数:3
相关论文
共 6 条
  • [1] Comparison of cytospat and pipelle endometrial biopsy instruments
    Antoni, J
    Folch, E
    Costa, J
    Foradada, CM
    Cayuela, E
    Combalia, N
    Rue, M
    [J]. EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 (01): : 57 - 61
  • [2] The diagnostic accuracy of outpatient miniature hysteroscopy in predicting premalignant and malignant endometrial lesions
    Bakour, SH
    Dwarakanath, LS
    Khan, KS
    Newton, JR
    [J]. GYNAECOLOGICAL ENDOSCOPY, 1999, 8 (03) : 143 - 148
  • [3] OUTPATIENT ENDOMETRIAL SAMPLING WITH THE PIPELLE CURETTE
    BENBARUCH, G
    SEIDMAN, DS
    SCHIFF, E
    MORAN, O
    MENCZER, J
    [J]. GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1994, 37 (04) : 260 - 262
  • [4] CHOO YC, 1985, OBSTET GYNECOL, V66, P225
  • [5] The incidence and management of failed pipelle sampling in a general outpatient clinic
    Gordon, SJ
    Westgate, J
    [J]. AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1999, 39 (01) : 115 - 118
  • [6] Logistic regression models in obstetrics and gynecology literature
    Khan, KS
    Chien, PFW
    Dwarakanath, LS
    [J]. OBSTETRICS AND GYNECOLOGY, 1999, 93 (06) : 1014 - 1020