Transcutaneous PCO2 to monitor noninvasive mechanical ventilation in adults -: Assessment of a new transcutaneous PCO2, device

被引:84
作者
Janssens, JP
Howarth-Frey, C
Chevrolet, JC
Abajo, B
Rochat, T
机构
[1] Univ Hosp Geneva, Div Surg Intens Care, Geneva, Switzerland
[2] Univ Hosp Geneva, Div Pulm Med, Geneva, Switzerland
关键词
blood gas monitoring; transcutaneous; carbon dioxide tension; intermittent positive pressure ventilation;
D O I
10.1378/chest.113.3.768
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The present study nas designed to analyze the usability of a commercially available, transcutaneous PCO2 (TcPCO2) sensor for monitoring noninvasive positive pressure ventilation (NPPV). Twenty-six hemodynamically stable patients with intra-arterial radial catheters were assessed. After stabilization of TcPCO2, arterial blood was analyzed and results were compared with TcPCO2 at time of sampling. To evaluate the drift of the signal, samples were taken hourly in five patients for 4 h while continuously recording TcPCO2. Finally, to assess for the response of the sensor to changes in PaCO2, six patients underwent continuous TcPCO2 recording while initiating or interrupting NPPV; arterial samples were analyzed before the event, and 1, 3, 5, 7, 9, and 20 min afterwards. Results: TcPCO2 and PaCO2 were tested over a range of 26 to 71 mm Hg, and were found to be closely correlated (r = 0.968, p < 0.0001); mean bias was 0.75 mm Hg. There was no significant drift of TcPCO2 as compared with PaCO2 over 4 h. The time of response or TcPCO2 to initiation or interruption of NPPV was < 60 s. An estimation of the lag time averaged 5 +/- 3 min (range, 1 to 9 min). Conclusion: TcPCO2 in hemodynamically stable adults was in excellent agreement with arterial measurements. The time of response to a change in ventilation was compatible with the aim of clinical monitoring of patients under NPPV.
引用
收藏
页码:768 / 773
页数:6
相关论文
共 27 条
[1]  
BLANCHETTE T, 1992, Respiratory Care, V37, P240
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   NONINVASIVE ASSESSMENT OF BLOOD-GASES [J].
CLARK, JS ;
VOTTERI, B ;
ARIAGNO, RL ;
CHEUNG, P ;
EICHHORN, JH ;
FALLAT, RJ ;
LEE, SE ;
NEWTH, CJL ;
ROTMAN, H ;
SUE, DY .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (01) :220-232
[4]   PATHOGENESIS OF CHEYNE-STOKES RESPIRATION IN PATIENTS WITH CONGESTIVE-HEART-FAILURE - RELATIONSHIP TO ARTERIAL PCO2 [J].
HANLY, P ;
ZUBERI, N ;
GRAY, R .
CHEST, 1993, 104 (04) :1079-1084
[5]   COMPARISON OF NONINVASIVE MEASUREMENTS OF CARBON-DIOXIDE TENSION DURING WITHDRAWAL FROM MECHANICAL VENTILATION [J].
HEALEY, CJ ;
FEDULLO, AJ ;
SWINBURNE, AJ ;
WAHL, GW .
CRITICAL CARE MEDICINE, 1987, 15 (08) :764-768
[6]   COMPARISON OF ARTERIAL, END-TIDAL AND TRANSCUTANEOUS PCO2 DURING MODERATE EXERCISE AND EXTERNAL CO2 LOADING IN HUMANS [J].
HOFFMANN, U ;
ESSFELD, D ;
STEGEMANN, J .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1990, 61 (1-2) :1-4
[7]  
JONES DJM, 1995, AM J RESP CRIT CARE, V152, P538
[8]   RESPONSE CHARACTERISTICS OF A DUAL TRANSCUTANEOUS OXYGEN CARBON-DIOXIDE MONITORING-SYSTEM [J].
KESTEN, S ;
CHAPMAN, KR ;
REBUCK, AS .
CHEST, 1991, 99 (05) :1211-1215
[9]   PERFORMANCE OF TRANS-CUTANEOUS PO2 AND PCO2 DUAL ELECTRODES IN ADULTS [J].
LANIGAN, C ;
PONTE, J ;
MOXHAM, J .
BRITISH JOURNAL OF ANAESTHESIA, 1988, 60 (06) :736-742
[10]  
Liebowitz RS, 1985, INTENS CARE MED, P33