Optimization of preconcentration and isolation for the determination of 15 phenols by supercritical-fluid extraction and gas chromatography with metallomesogenic stationary phase

被引:14
作者
Chen, JL [1 ]
Liu, CY
机构
[1] Chung Shan Med Univ, Dept Occupat Safety & Hlth, Taichung, Taiwan
[2] Natl Taiwan Univ, Dept Chem, Taipei 10764, Taiwan
关键词
phenols; XAD-4; SFE; factorial design; metallomesogen; capillary; GC; soil;
D O I
10.1016/j.aca.2004.08.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Based on the merits of well-established capillary gas chromatography (GC), metallomesogenic polymer was used as the stationary phase and flame ionization detector (FID) was used as the detector, the analysis of phenolic compounds explored the possibility of application in complex matrices. We proposed the method combined supercritical-fluid extraction (SFE) of phenolic compounds,, which had been enriched on the solid supports of XAD-4 resins, and then with their determinations by capillary GC-FID. The SFE parameters, suitable for 15 phenols simultaneously adsorbed onto XAD-4 resins in aqueous solution were assessed by a 4(5) factorial design method. The best results were 5 min static time, 10 min dynamic time, 0.25 ml methanol spiked, 80degreesC oven temperature and 410 atm CO pressure. Also. other parametric conditions for specific phenols were revealed and analyzed. In the comparison with Soxhlet extraction with regard to the recoveries and reproducibility, the developed SFE was quite superior and helped to reduce the detection limit of aqueous samples to 10(-2)-fold. Eventually. the polluted soils near a pharmaceutical factory were primarily tested and given the probable distribution. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 22 条
[1]  
Abu-Shammala F, 1999, ANAL LETT, V32, P3083
[2]   SIMULTANEOUS DETERMINATION OF 27 PHENOLS AND HERBICIDES IN WATER BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH MULTIELECTRODE ELECTROCHEMICAL DETECTION [J].
ACHILLI, G ;
CELLERINO, GP ;
DERIL, GM ;
BIRD, S .
JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) :357-362
[3]   IDENTIFICATION AND QUANTIFICATION OF MONOHYDROXYBENZENES, DIHYDROXYBENZENES AND TRIHYDROXYBENZENES (PHENOLS) AT TRACE CONCENTRATIONS IN SEAWATER BY AQUEOUS ACETYLATION AND GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS [J].
BOYD, TJ .
JOURNAL OF CHROMATOGRAPHY A, 1994, 662 (02) :281-292
[4]   Preconcentration of contaminants in water analysis [J].
Bruzzoniti, MC ;
Sarzanini, C ;
Mentasti, E .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :289-309
[5]   Chelating resin sorption followed by supercritical fluid extraction and liquid chromatographic determination of aluminum in liquid samples [J].
Chen, JL ;
Liu, CY .
ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) :125-132
[6]   Trace determination of phenols in natural waters - Extraction by a new graphitized carbon black cartridge followed by liquid chromatography and re-analysis after phenol derivatization [J].
DiCorcia, A ;
Bellioni, A ;
Madbouly, MD ;
Marchese, S .
JOURNAL OF CHROMATOGRAPHY A, 1996, 733 (1-2) :383-393
[7]  
FISHER JA, 1997, SCOTT ENV SCI TECHNO, V31, P1120
[8]   Determination of phenols in soil by supercritical fluid extraction-capillary electrochromatography [J].
Fung, YS ;
Long, YH .
JOURNAL OF CHROMATOGRAPHY A, 2001, 907 (1-2) :301-311
[9]   DIRECT COMPARISON OF SOXHLET AND LOW-TEMPERATURE AND HIGH-TEMPERATURE SUPERCRITICAL CO2 EXTRACTION EFFICIENCIES OF ORGANICS FROM ENVIRONMENTAL SOLIDS [J].
HAWTHORNE, SB ;
MILLER, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :4005-4012
[10]   Determination of pentachlorophenol and its oil solvent in wood pole samples by SFE and GC with postcolumn flow splitting for simultaneous detection of the species [J].
Leblanc, YG ;
Gilbert, R ;
Hubert, J .
ANALYTICAL CHEMISTRY, 1999, 71 (01) :78-85