Fluorescence correlation spectroscopy in small cytosolic compartments depends critically on the diffusion model used

被引:93
作者
Gennerich, A [1 ]
Schild, D [1 ]
机构
[1] Univ Gottingen, Abt Mol Neurophysiol, Inst Physiol, D-37073 Gottingen, Germany
关键词
D O I
10.1016/S0006-3495(00)76561-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Fluorescence correlation spectroscopy (FCS) is a powerful technique for measuring low concentrations of fluorescent molecules and their diffusion constants. In the standard case, fluorescence fluctuations are measured in an open detection volume defined by the confocal optics. However, if FCS measurements are carried out in cellular processes that confine the detection volume, the standard FCS model leads to erroneous results. In this paper, we derive a modified FCS model that takes into account the confinement of the detection volume. Using this model, we have carried out the first FCS measurements in dendrites of cultured neurons. We further derive, for the case of confined diffusion, the limits within which the standard two- and three-dimensional diffusion models give reliable results.
引用
收藏
页码:3294 / 3306
页数:13
相关论文
共 15 条
[1]   FLUORESCENCE CORRELATION SPECTROSCOPY AS A PROBE OF MOLECULAR-DYNAMICS [J].
ARAGON, SR ;
PECORA, R .
JOURNAL OF CHEMICAL PHYSICS, 1976, 64 (04) :1791-1803
[2]   2-PHOTON FLUORESCENCE CORRELATION SPECTROSCOPY - METHOD AND APPLICATION TO THE INTRACELLULAR ENVIRONMENT [J].
BERLAND, KM ;
SO, PTC ;
GRATTON, E .
BIOPHYSICAL JOURNAL, 1995, 68 (02) :694-701
[3]  
Bischofberger J, 1995, ADV BIOSCI, V93, P133
[4]   DIFFERENT SPATIAL PATTERNS OF [CA2+] INCREASE CAUSED BY N-TYPE AND L-TYPE CA2+ CHANNEL ACTIVATION IN FROG OLFACTORY-BULB NEURONS [J].
BISCHOFBERGER, J ;
SCHILD, D .
JOURNAL OF PHYSIOLOGY-LONDON, 1995, 487 (02) :305-317
[5]   Fluorescence correlation microscopy of cells in the presence of autofluorescence [J].
Brock, R ;
Hink, MA ;
Jovin, TM .
BIOPHYSICAL JOURNAL, 1998, 75 (05) :2547-2557
[6]   FLUORESCENCE CORRELATION SPECTROSCOPY .1. CONCEPTUAL BASIS AND THEORY [J].
ELSON, EL ;
MAGDE, D .
BIOPOLYMERS, 1974, 13 (01) :1-27
[7]   STATISTICAL ACCURACY IN FLUORESCENCE CORRELATION SPECTROSCOPY [J].
KOPPEL, DE .
PHYSICAL REVIEW A, 1974, 10 (06) :1938-1945
[8]  
Nieuwkoop PD, 1956, NORMAL TABLE XENOPUS
[9]  
Papoulis A., 1991, PROBABILITY RANDOM V
[10]   Intranuclear diffusion and hybridization state of oligonucleotides measured by fluorescence correlation spectroscopy in living cells [J].
Politz, JC ;
Browne, ES ;
Wolf, DE ;
Pederson, T .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (11) :6043-6048