Accuracy of the precordial V-quick® patch in persons with cardiac or pulmonary disease

被引:2
作者
Baas, LS
Beery, TA
Allen, GA
Ware, S
Lamba, S
Abraham, WT
机构
[1] Univ Cincinnati, Coll Nursing, Cincinnati, OH 45221 USA
[2] Miami Univ, Oxford, OH 45056 USA
[3] VA Med Ctr, Dept Neurol, Cincinnati, OH USA
[4] Ohio State Univ, Med Ctr, Div Cardiol, Columbus, OH 43210 USA
关键词
12-lead electrocardiogram; electrodes; prehospital EKG;
D O I
10.1016/S0736-4679(02)00718-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The aim of this study was to demonstrate the equivalence of 12-Lead Electrocardiograms (EKG) obtained with the new V-Quick(R) patch and traditional tab-style electrodes. Using a within-subject design, a convenience sample of 100 subjects with either cardiac or pulmonary disease underwent two 12-lead EKGs, one with the traditional tab-style electrodes and one with the precordial patch. Computer-generated measurements of waveform axes and amplitude were obtained for both EKGs. Comparison of mean and 95% confidence intervals revealed no significant differences in Q, R or S wave amplitude across the six precordial leads. Furthermore, a four-factor ANOVA found no significant difference (p > 0.05) in the Q, R and S wave amplitude between the type of electrode, gender and type of disease. A subset of 29 EKGs read by three experts found intra- (.90) and inter-rater (.84) reliability to be strong. In conclusion, the precordial V-Quick(R) patch provided equivalent EKGs to those obtained using standard tab-style electrodes. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:131 / 139
页数:9
相关论文
共 21 条
[1]   THE DIAGNOSTIC IMPACT OF PREHOSPITAL 12-LEAD ELECTROCARDIOGRAPHY [J].
AUFDERHEIDE, TP ;
HENDLEY, GE ;
THAKUR, RK ;
MATEER, JR ;
STUEVEN, HA ;
OLSON, DW ;
HARGARTEN, KM ;
LAITINEN, F ;
ROBINSON, N ;
PREUSS, KC ;
HOFFMAN, RG .
ANNALS OF EMERGENCY MEDICINE, 1990, 19 (11) :1280-1287
[2]   The prehospital electrocardiogram in acute myocardial infarction: Is its full potential being realized? [J].
Canto, JG ;
Rogers, WJ ;
Bowlby, LJ ;
French, WJ ;
Pearce, DJ ;
Weaver, WD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (03) :498-505
[3]  
Carmines E.G., 1980, RELIABILITY VALIDITY
[4]  
Chou T-C., 1996, Electrocardiography in Clinical Practice: Adult and Pediatric
[5]  
CLOCHESY JM, 1991, HEART LUNG, V20, P27
[6]  
Cronbach L.J., 1984, ESSENTIALS PSYCHOL T
[7]   A RELATIONSHIP BETWEEN BIOELECTRICAL IMPEDANCE AND TOTAL-BODY WATER IN YOUNG-ADULTS [J].
DAVIES, PSW ;
JAGGER, SE ;
REILLY, JJ .
ANNALS OF HUMAN BIOLOGY, 1990, 17 (05) :445-448
[8]   PREHOSPITAL DIAGNOSIS AND TREATMENT OF ACUTE MYOCARDIAL-INFARCTION - A NORTH-SOUTH PERSPECTIVE [J].
GIBLER, WB ;
KEREIAKES, DJ ;
DEAN, EN ;
MARTIN, L ;
ANDERSON, L ;
ABBOTTSMITH, CW ;
BLANTON, J ;
BLANTON, D ;
MORRIS, JA ;
GIBLER, CD ;
ERB, RE ;
TEICHMAN, SL .
AMERICAN HEART JOURNAL, 1991, 121 (01) :1-11
[9]   THE EFFECTS OF COMPUTER-ASSISTED ELECTROCARDIOGRAPHIC INTERPRETATION ON PHYSICIANS DIAGNOSTIC DECISIONS [J].
HILLSON, SD ;
CONNELLY, DP ;
LIU, YL .
MEDICAL DECISION MAKING, 1995, 15 (02) :107-112
[10]  
KAHN MA, 1993, BR J CLIN PRACT, V47, P183