A facility for controlled exposure of pigs to airborne dusts and gases

被引:12
作者
Demmers, TGM
Wathes, CM
Richards, PA
Teer, N
Taylor, LL
Bland, V
Goodman, J
Armstrong, D
Chennells, D
Done, SH
Hartung, J
机构
[1] Silsoe Res Inst, Bioengn Div, Silsoe MK45 4HS, Beds, England
[2] Meat & Livestock Commiss, Milton Keynes MK45 1AH, Bucks, England
[3] Acorn Vet Surg, Brickhill MK41 7HN, Beds, England
[4] Vet Labs Agcy, Weybridge KT15 3NB, Surrey, England
[5] Tierarztlichen Hsch Hannover, Inst Tierzucht & Tierhyg, D-30559 Hannover, Germany
关键词
D O I
10.1016/S1537-5110(02)00243-X
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
A facility has been developed for a study in which, for 6 weeks, groups of weaner pigs (960 in total) were exposed to controlled concentrations of airborne dust (nominally 0, 2.5, 5 or 10 mg m(-3) inhalable fraction) and ammonia (nominally 0, 10, 20 or 40 parts per million, ppm) and the effects on production and respiratory disease measured. The facility comprised five rooms, each holding 24 pigs. Each room was ventilated mechanically at a constant rate of either 30 or 40 air changes per hour in the Winter and Summer, respectively, to minimise the background concentration of pollutants. An artificial pig dust has been developed, though setting the specifications for composition, particle size distribution and microbial content was hampered by the lack of published values for these parameters. The dust was manufactured from feed, barley straw and faeces, mixed by weight in the proportions 0.5:0.1:0.4. The ingredients were oven dried to inactivate microbes and remove moisture and oil binders, milled by a hammer mill and then an air classifier mill, and mixed. This dust was then injected into the supply air of each room via a venturi nozzle fed from an agitated hopper. The size distribution of this dust approximated published values for piggery dust. The dust concentration was monitored with a tribo-electric sensor, which was calibrated against an aerodynamic particle sizer and gravimetric samplers. Ammonia was also injected into the supply air; its rate was controlled with mass flow controllers and its concentration was measured continuously with a NO chemiluminescence gas analyser after catalytic conversion of NH3 to NO at 750degreesC. The monitoring and control system was controlled by a computer, which included a safety system to terminate pollutant generation if set limits are exceeded. The facility has been used successfully and two batches of pigs have been tested satisfactorily. (C) 2003 Silsoe Research Institute. All rights reserved.
引用
收藏
页码:217 / 230
页数:14
相关论文
共 20 条
[1]  
CLARK S, 1983, AM IND HYG ASSOC J, V44, P537, DOI 10.1080/15298668391405265
[2]  
CURTIS SE, 1975, J ANIM SCI, V41, P1502, DOI 10.2527/jas1975.4151502x
[3]  
De Boer S., 1988, EFFECTS QUALITY ENV
[4]   Ammonia emissions from two mechanically ventilated UK livestock buildings [J].
Demmers, TGM ;
Burgess, LR ;
Short, JL ;
Philips, VR ;
Clark, JA ;
Wathes, CM .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (02) :217-227
[5]  
DIEKMAN MA, 1993, AM J VET RES, V54, P2128
[6]  
DOIG PA, 1971, J AM VET MED ASSOC, V159, P1353
[7]   ENVIRONMENTAL-FACTORS AFFECTING THE SEVERITY OF PNEUMONIA IN PIGS [J].
DONE, SH .
VETERINARY RECORD, 1991, 128 (25) :582-586
[8]   CHARACTERIZATION OF DUSTS COLLECTED FROM SWINE CONFINEMENT BUILDINGS [J].
DONHAM, KJ ;
SCALLON, LJ ;
POPENDORF, W ;
TREUHAFT, MW ;
ROBERTS, RC .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1986, 47 (07) :404-410
[9]   EFFECTS OF AERIAL AMMONIA ON GROWTH AND HEALTH OF YOUNG-PIGS [J].
DRUMMOND, JG ;
CURTIS, SE ;
SIMON, J ;
NORTON, HW .
JOURNAL OF ANIMAL SCIENCE, 1980, 50 (06) :1085-1091
[10]   Contributory and exacerbating roles of gaseous ammonia and organic dust in the etiology of atrophic rhinitis [J].
Hamilton, TDC ;
Roe, JM ;
Hayes, CM ;
Jones, P ;
Pearson, GR ;
Webster, AJF .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1999, 6 (02) :199-203