Total volatile organic compounds (TVOC) in indoor air quality investigations

被引:187
作者
Molhave, L [1 ]
Clausen, G
Berglund, B
de Ceaurriz, J
Kettrup, A
Lindvall, T
Maroni, M
Pickering, AC
Risse, U
Rothweiler, H
Seifert, B
Younes, M
机构
[1] Aarhus Univ, Inst Environm & Occupat Med, DK-8000 Aarhus C, Denmark
[2] Tech Univ Denmark, Lab Heating & Air Conditioning, Copenhagen, Denmark
[3] Univ Stockholm, Dept Psychiat, Stockholm, Sweden
[4] Fac Pharm Chatenay Malabry, Lab Chim & Toxicol Environm, Chatenay Malabry, France
[5] GSF Forschungszentrum Umwelt & Gesundheit GMBH, Inst Okol Chem, Oberschleissheim, Germany
[6] Karolinska Inst, Inst Environm Med, S-10401 Stockholm, Sweden
[7] Ctr Int Sicurezza Antiparassitari, Busto Garolfo, Italy
[8] Wythenshawe Hosp, NW Lung Ctr, Manchester M23 9LT, Lancs, England
[9] Stadt Kloten, Umwelt & Gesundheit, Kloten, Germany
[10] Umweltbundesamt, Inst Wasser Boden & Lufthyg, Berlin, Germany
[11] WHO, CH-1211 Geneva, Switzerland
关键词
VOCs; TVOC; health effects; sensory effects; sampling and analysis;
D O I
10.1111/j.1600-0668.1997.00002.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The amount of volatile organic compounds (VOCs) in indoor air, usually called TVOC (total volatile organic compounds), has been measured using different definitions and techniques which yield different results. This report recommends a definition of TVOC referring to a specified range of VOCs and it proposes a method for the measurement of this TVOC entity. Within the specified range, the measured concentrations of identified VOCs (including 64 target compounds) are summed up, concentrations of non-identified compounds in toluene equivalents are added and, together with the identified VOCs, they give the TVOC value. The report reviews the TVOC concept with respect to its usefulness for exposure assessment and control and for the prediction of health or comfort effects. Although the report concludes that at present it is not possible to use TVOC as an effect predictor, it affirms the usefulness of TVOC for characterizing indoor pollution and for improving source control as required from the points of view of health, comfort, energy efficiency and sustainability. (C) Indoor Air (1997).
引用
收藏
页码:225 / 240
页数:16
相关论文
共 69 条
  • [1] [Anonymous], 1993, Journal of Indoor Air, DOI DOI 10.1111/J.1600-0668.1993.T01-1-00002.X
  • [2] PSYCHOLOGICAL PROCESSING OF ODOR MIXTURES
    BERGLUND, B
    BERGLUND, U
    LINDVALL, T
    [J]. PSYCHOLOGICAL REVIEW, 1976, 83 (06) : 432 - 441
  • [3] BERGLUND B, 1993, 764 STOCKH U DEP PSY
  • [4] Berglund B., 1993, FECHNER DAY 93, P35
  • [5] BERGLUND B, 1992, ENVIRON INT, V8, P395
  • [6] Berglund B., 1992, Indoor Air, V2, P2, DOI [10.1111/j.1600-0668.1992.02-21.x, DOI 10.1111/J.1600-0668.1992.02-21.X]
  • [7] Berglund B, 1982, ENVIRON INT, V8, P327
  • [8] BERGLUND B, 1989, CLIMA 2000, V3, P13
  • [9] CONCENTRATIONS OF VOLATILE ORGANIC-COMPOUNDS IN INDOOR AIR - A REVIEW
    BROWN, SK
    SIM, MR
    ABRAMSON, MJ
    GRAY, CN
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02): : 123 - 134
  • [10] CLAUSEN GH, 1985, P CLIMA 2000 COP, V4, P345