Temporal integration: reflections in the M100 of the auditory evoked field

被引:29
作者
Gage, NM
Roberts, TPL
机构
[1] Univ Calif San Francisco, Dept Radiol, Biomagnet Imaging Lab, San Francisco, CA 94143 USA
[2] Univ Calif Irvine, Dept Cognit Sci, Irvine, CA 92717 USA
关键词
auditory cortex; evoked response; magnetoencephalography; M100; stimulus duration; sound onset; temporal encoding; temporal integration; timing;
D O I
10.1097/00001756-200008210-00023
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Previous work investigating temporal integration in the formation of the auditory evoked field component, M100, indicates an accumulation of stimulus attribute information in the processes underlying the M100 response with a temporal window for this integration of similar to 25-32 ms. We investigate the influence of stimulus duration on M100 amplitude using sinusoidal tone stimuli of increasing duration under two experimental conditions: constant intensity, and constant energy (with stimulus intensity decreasing as duration in-creased). We report that M100 amplitude increases with stimulus duration up to a point of saturation at similar to 40 ms; importantly, this dependence holds in both experimental conditions, despite differing stimulus intensities. Thus we conclude that (within this similar to 40 ms temporal window) stimulus duration itself, and not integrated energy, determines M100 amplitude. (C) 2000 Lippincott Williams & Wilkins.
引用
收藏
页码:2723 / 2726
页数:4
相关论文