Measurements on concorde of the cosmic radiation field at aviation altitudes

被引:23
作者
Bartlett, DT [1 ]
Hager, LG
Irvine, D
Bagshaw, M
机构
[1] Natl Radiol Protect Board, Chilton OX11 0RQ, Oxon, England
[2] British Airways Hlth Serv, Harmondsworth UB7 0GB, England
关键词
D O I
10.1093/oxfordjournals.rpd.a033246
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The results are reported of the first three years of a five year measurement programme of average route doses on board Concorde. Measurements of the complex cosmic radiation field are made with a passive survey meter comprising thermoluminescent detectors and etched track detectors. The 15% determination level for total dose equivalent is 100 mu Sv. The evidence is that the passive survey meter provides a reliable determination of route dose. The average route effective dose for a return flight by Concorde between London and New York measured during the period January 1997 to October 1999, was 74 mu Sv.
引用
收藏
页码:365 / 376
页数:12
相关论文
共 48 条
[1]   Ten years on: The NRPB PADC neutron personal monitoring service [J].
Bartlett, DT ;
Steele, JD ;
Tanner, RJ ;
Gilvin, PJ ;
Shaw, PV ;
Lavelle, J .
RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) :161-163
[2]  
BARTLETT DT, 2000, RADIAT RES, V2, P719
[3]  
BENBOW TG, 1968, P 57 INT AER INSTR S, P1
[4]  
BIRATTARI C, 1998, P 3 SPEC M SHIELD AS, P219
[5]  
BLOMGREN J, 1997, COMMUNICATION
[6]  
DAVIES DM, 1993, RADIAT PROT DOSIM, V48, P121
[7]  
FASSO A, 1994, P WORKSH SIM ACC RAD, P134
[8]   Fluence to dose equivalent conversion data and effective quality factors for high energy neutrons [J].
Ferrari, A ;
Pelliccioni, M .
RADIATION PROTECTION DOSIMETRY, 1998, 76 (04) :215-224
[9]   Fluence to effective dose conversion coefficients for neutrons up to 10 TeV [J].
Ferrari, A ;
Pelliccioni, M ;
Pillon, M .
RADIATION PROTECTION DOSIMETRY, 1997, 71 (03) :165-173
[10]   Individual neutron monitoring with CR-39 detectors at an accelerator centre [J].
Fiechtner, A ;
Wernli, C .
RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) :35-38