A comparison of five techniques for detecting cardiac activity in infants

被引:37
作者
Inagawa, G
Morimura, N
Miwa, T
Okuda, K
Hirata, M
Hiroki, K
机构
[1] Yokohama City Univ, Sch Med, Dept Anesthesiol, Kanazawa Ku, Yokohama, Kanagawa 2360004, Japan
[2] Kanagawa Childrens Med Ctr, Dept Anesthesia, Yokohama, Kanagawa, Japan
[3] Yokohama City Univ, Med Ctr, Crit Care & Emergency Ctr, Yokohama, Kanagawa 232, Japan
来源
PAEDIATRIC ANAESTHESIA | 2003年 / 13卷 / 02期
关键词
cardiopulmonary resuscitation; infant; pulse; direct auscultation technique;
D O I
10.1046/j.1460-9592.2003.00970.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background : The new guidelines for cardiopulmonary resuscitation recommend that laypersons should begin chest compressions without checking for a pulse because the pulse check has serious limitations in accuracy. We determined the efficacy of the most suitable method to search for cardiac activity in infants. Methods : Twenty-eight nurses tried to detect infants' cardiac activity and determined their heart rates with five different techniques: palpation of brachial pulse, carotid pulse, femoral pulse, apical impulse and auscultation of apical impulse with the naked ear (direct auscultation technique). Results : The mean time interval required to find the pulse within 30 s in the auscultation, the apical, the brachial, the carotid and the femoral were 2.4 +/- 1.2, 3.5 +/- 2.7, 4.0 +/- 2.7, 9.9 +/- 7.0 and 9.1 +/- 5.9 s, respectively. The required time was significantly shorter in the auscultation method than in the palpation of carotid and femoral pulses. The percentage and 95% confidence intervals (95% CI) of pulses identified within 10 s (= the number of the correct identified within 10 s/the number of all cases) in auscultation, apical, brachial, carotid and femoral palpations were 100.0% (95% CI 51.8, 100), 75.0% (95% CI 28.9, 89.3), 73.1% (95% CI 52.2, 88.4), 50.0% (95% CI 30.6, 69.4) and 42.9% (95% CI 24.5, 62.8), respectively. These values were greater in the auscultation method than in all the palpation methods. Conclusions : The direct auscultation technique was more rapid and accurate than any other techniques to determine cardiac activity without instruments. It is suggested that direct a auscultation technique is also superior to the palpation of brachial artery in cardiopulmonary resuscitation in infants.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 17 条
[1]   Skills of lay people in checking the carotid pulse [J].
Bahr, J ;
Klingler, H ;
Panzer, W ;
Rode, H ;
Kettler, D .
RESUSCITATION, 1997, 35 (01) :23-26
[2]   COMPARISON OF 2 TECHNIQUES FOR DETECTING CARDIAC ACTIVITY IN INFANTS [J].
CAVALLARO, DL ;
MELKER, RJ .
CRITICAL CARE MEDICINE, 1983, 11 (03) :189-190
[3]   Cardiopulmonary resuscitation techniques and instruction: When does evidence justify revision? [J].
Cummins, RO ;
Hazinski, MF .
ANNALS OF EMERGENCY MEDICINE, 1999, 34 (06) :780-784
[4]   Checking the carotid pulse check: Diagnostic accuracy of first responders in patients with and without a pulse [J].
Eberle, B ;
Dick, WF ;
Schneider, T ;
Wisser, G ;
Doetsch, S ;
Tzanova, I .
RESUSCITATION, 1996, 33 (02) :107-116
[5]  
FLESCHE CW, 1994, CIRCULATION, V90, P288
[6]  
FLESCHE CW, 1994, RESUSCITATION, V28, pS25
[7]   DETERMINING THE PULSE FOR INFANT CPR - TIME FOR A CHANGE [J].
LEE, CJ ;
BULLOCK, LJ .
MILITARY MEDICINE, 1991, 156 (04) :190-193
[8]   The palpation of pulses [J].
Mather, C .
ANAESTHESIA, 1996, 51 (02) :189-191
[9]  
Monsieurs K., 1996, RESUSCITATION, V31, pS3
[10]   Pediatric resuscitation - An advisory statement from the Pediatric Working Group of the International Liaison Committee on Resuscitation [J].
Nadkarni, V ;
Hazinski, MF ;
Zideman, D ;
Kattwinkel, J ;
Quan, L ;
Bingham, R ;
Zaritsky, A ;
Bland, J ;
Kramer, E ;
Tiballs, J .
CIRCULATION, 1997, 95 (08) :2185-2195