A flow cytometric immunoassay for β2-microglobulin in whole blood

被引:12
作者
Bishop, JE [1 ]
Davis, KA [1 ]
机构
[1] Becton Dickinson Immunocytometry Syst, San Jose, CA 95131 USA
关键词
immunofluorescence assay; flow cytometry; beta; 2-microglobulin; microspheres; immunoassay;
D O I
10.1016/S0022-1759(97)00179-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flow cytometers can discriminate a single particle type in ar. unwashed whole blood sample. Utilizing this capability, we devised a homogeneous bead-immobilized sandwich immunoassay for soluble beta(2)M (beta(2)-microglobulin) in whole blood, utilizing an antibody that discriminates soluble from cellular beta(2)M. A 4 mu m bead was chosen that fluoresces only in a FACScan(TM) flow cytometer's FL3 channel, thus allowing triggering on this bead to the exclusion of the many blood cell events. The bead was adsorbed with a capture antibody (clone A7801) which binds only to soluble and not to cellular beta(2)M. This antibody appears to recognize an epitope on beta(2)M Which interfaces to the heavy chain of cellular Class I MHC molecules. The signal antibody (PE conjugate of clone L376, emitting in the FL2 channel) binds to both soluble and cellular beta(2)M (present in roughly equal amounts in normal blood), The various parameters required for a flow cytometric immunoassay were optimized. The 4 mu m sized bead was adequately large to give a near full scale signal at saturation. The relative amounts of signal antibody and capture beads were balanced to give a low blank, minimal 'hook effect', and reasonable event rate on the flow cytometer. The amount of blood added was selected to give a signal near the bottom of the immunassay range for normals with the higher range available for clinical samples. The assay requires no washing, minimizes blood handling, and has a working range (2.5 decades) that is compatible with the biological range of beta(2)M concentrations with a single blood dilution. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:79 / 87
页数:9
相关论文
共 28 条
  • [1] BANGS LB, 1992, LATEX COURSE
  • [2] BETHEA M, 1990, ANN CLIN LAB SCI, V20, P163
  • [3] BISHOP JE, 1994, CYTOMETRY, V7, pD312
  • [4] THE PHYSICAL AND FUNCTIONAL-BEHAVIOR OF CAPTURE ANTIBODIES ADSORBED ON POLYSTYRENE
    BUTLER, JE
    NI, L
    NESSLER, R
    JOSHI, KS
    SUTER, M
    ROSENBERG, B
    CHANG, J
    BROWN, WR
    CANTARERO, LA
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 150 (1-2) : 77 - 90
  • [5] THE PROGNOSTIC VALUE OF CELLULAR AND SEROLOGIC MARKERS IN INFECTION WITH HUMAN IMMUNODEFICIENCY VIRUS TYPE-1
    FAHEY, JL
    TAYLOR, JMG
    DETELS, R
    HOFMANN, B
    MELMED, R
    NISHANIAN, P
    GIORGI, JV
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1990, 322 (03) : 166 - 172
  • [6] FERNANDO SA, 1992, J IMMUNOL METHODS, V151, P47
  • [7] A SEQUENTIAL BINDING ASSAY WITH A WORKING RANGE EXTENDING BEYOND 7 ORDERS OF MAGNITUDE
    FRENGEN, J
    NUSTAD, K
    SCHMID, R
    LINDMO, T
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 178 (01) : 131 - 140
  • [8] DUAL ANALYTE ASSAY BASED ON PARTICLE TYPES OF DIFFERENT SIZE MEASURED BY FLOW-CYTOMETRY
    FRENGEN, J
    LINDMO, T
    PAUS, E
    SCHMID, R
    NUSTAD, K
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 178 (01) : 141 - 151
  • [9] FRENGEN J, 1993, CLIN CHEM, V39, P2174
  • [10] FRENGEN J, 1994, CLIN CHEM, V40, P420