Treatment of type III endoleak with an aortouniiliac stent graft

被引:29
作者
Teruya, TH
Ayerdi, J
Solis, MM
Abou-Zamzam, AM
Ballard, JL
McLafferty, RB
Hodgson, KJ
机构
[1] Loma Linda Univ, Med Ctr, Div Vasc Surg, Loma Linda, CA 92354 USA
[2] So Illinois Univ, Sch Med, Dept Surg, Div Peripheral Vasc Surg, Springfield, IL 62794 USA
关键词
D O I
10.1007/s10016-001-0395-y
中图分类号
R61 [外科手术学];
学科分类号
摘要
The purpose of this study was to present a novel treatment method for repair of a type III endoleak due to separation of modular components of an AneuRx (Medtronic AVE, Sunnyvalle, CA) stent graft as a result of graft kinking. A 73-year-old male had undergone endovascular repair of a 8.2-cm abdominal aortic aneurysm (AAA) 2 years previously. An aortic extender cuff was required to secure the proximal graft. Computed tomographic (CT) follow-up revealed a type III endoleak at 6-month follow-up. Plain radiographs showed separation between the main graft body and the aortic extender cuff. A second custom-made 28 mm x 5.5cm aortic extender cuff was placed to seal the type III endoleak. Follow-up CT showed a persistent endoleak with an increase in AAA size to 10.5 cm. The patient underwent remedial AAA repair with an aortouniiliac endograft placed within the previous stent graft and a femorofemoral bypass. At 3-month follow-up there was no detectable endoleak. This constitutes an alternative endovascular therapy for modular device separation (type-III endoleak) after endoluminal AAA repair in patients who cannot undergo repair with a second bifurcated graft.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 18 条
[1]  
Boyle JR, 2000, J ENDOVASC THER, V7, P359, DOI 10.1583/1545-1550(2000)007<0359:EARATI>2.0.CO
[2]  
2
[3]   Initial experience with endovascular aneurysm repair: Comparison of early results with outcome of conventional open repair [J].
Brewster, DC ;
Geller, SC ;
Kaufman, JA ;
Cambria, RP ;
Gertler, JP ;
LaMuraglia, GM ;
Atamian, S ;
Abbott, WM .
JOURNAL OF VASCULAR SURGERY, 1998, 27 (06) :992-1003
[4]   Early complications and endoleaks after endovascular abdominal aortic aneurysm repair: Report of a multicenter study - Discussion [J].
Parodi, JC ;
Buth, J .
JOURNAL OF VASCULAR SURGERY, 2000, 31 (01) :145-146
[5]  
Harris P, 1999, J ENDOVASC SURG, V6, P11, DOI 10.1583/1074-6218(1999)006<0011:LASFEA>2.0.CO
[6]  
2
[7]   Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience [J].
Harris, PL ;
Vallabhaneni, SR ;
Desgranges, P ;
Bacquemin, JP ;
van Marrewijk, C ;
Laheij, RJF .
JOURNAL OF VASCULAR SURGERY, 2000, 32 (04) :739-749
[8]   Comparison of cognitive function and quality of life after endovascular or conventional aortic aneurysm repair [J].
Lloyd, AJ ;
Boyle, J ;
Bell, PRF ;
Thompson, MM .
BRITISH JOURNAL OF SURGERY, 2000, 87 (04) :443-447
[9]   Aorto-uni-iliac endograft for complex aortoiliac aneurysms compared with tube/bifurcation endografts: Results of the EVT/Guidant trials [J].
Moore, WS ;
Brewster, DC ;
Bernhard, VM .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (02) :S11-S20
[10]   Late abdominal aortic aneurysm rupture after AneuRx repair: A report of three cases [J].
Politz, JK ;
Newman, VS ;
Stewart, VT .
JOURNAL OF VASCULAR SURGERY, 2000, 31 (03) :599-606