Determination of linuron in water samples by high performance liquid chromatography after preconcentration with octadecyl silanized magnetite

被引:24
作者
Katsumata, Hideyuki [1 ]
Asai, Hayato
Kaneco, Satoshi
Suzuki, Tohru
Ohta, Kiyohisa
机构
[1] Mie Univ, Dept Chem, Grad Sch Engn, Tsu, Mie 5148507, Japan
[2] Mie Univ, Environm Preservat Ctr, Tsu, Mie 5148507, Japan
关键词
linuron determination; preconcentration; adsorption; octadecyl silanized magnetite; HPLC;
D O I
10.1016/j.microc.2006.07.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective batch adsorption method is proposed for the preconcentration and determination of linuron. Linuron was preconcentrated on octadecyl silanized (ODS) magnetite as an adsorbent and then determined by high performance liquid chromatography (HPLC). Several parameters on the recovery of the analyte were investigated. The experimental results showed that it was possible to obtain sufficient preconcentration efficiency when the solution pH was 6 using 100 mL of sample solution containing 1.0 mu g of linuron and 3 mL of ethanol as a desorption solution. Recovery of linuron was 50.7 +/- 1.9% with a relative standard deviation for five determinations of 3.0% under optimum conditions. The calibration curve of linuron was linear up to 200 ng mL(-1) with a correlation coefficient of 0.998 and the detection limit (3S/N) was 1.0 ng mL(-1). The capacity of the adsorbent was also examined and found to be 0.15 mg g(-1) for linuron. ODS-magnetite is suitable for repeated use without decreasing recovery at least 4 adsorption-desorption cycles. The proposed method was successfully applied to the determination of linuron in river water with high precision and accuracy. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:285 / 289
页数:5
相关论文
共 24 条
[1]   Determination and quantitation of sulfonylurea and urea herbicides in water samples using liquid chromatography with electrospray ionization mass spectrometric detection [J].
Ayano, E ;
Kanazawa, H ;
Ando, M ;
Nishimura, T .
ANALYTICA CHIMICA ACTA, 2004, 507 (02) :211-218
[2]   SEWAGE CLARIFICATION WITH MAGNETITE PARTICLES [J].
BOOKER, NA ;
KEIR, D ;
PRIESTLEY, AJ ;
RITCHIE, CB ;
SUDARMANA, DL ;
WOODS, MA .
WATER SCIENCE AND TECHNOLOGY, 1991, 23 (7-9) :1703-1712
[3]   Simultaneous determination of phenyl- and sulfonylurea herbicides in water by solid-phase extraction and liquid chromatography with UV diode array or mass spectrometric detection [J].
Carabias-Martínez, R ;
Rodríguez-Gonzalo, E ;
Herrero-Hernández, E ;
Hernández-Méndez, J .
ANALYTICA CHIMICA ACTA, 2004, 517 (1-2) :71-79
[4]  
CHINON S, 1993, ENVIRON SCI TECHNOL, V27, P135
[5]   INVESTIGATION OF A MECHANISM FOR LEYDIG-CELL TUMORIGENESIS BY LINURON IN RATS [J].
COOK, JC ;
MULLIN, LS ;
FRAME, SR ;
BIEGEL, LB .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1993, 119 (02) :195-204
[6]   CHROMATOGRAPHIC BEHAVIOR OF PHENYLUREA PESTICIDES IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH NITRILE-BONDED AND AMINO-BONDED STATIONARY PHASES [J].
FISCHER, J ;
JANDERA, P .
JOURNAL OF CHROMATOGRAPHY A, 1994, 684 (01) :77-92
[7]   Separation of phenylurea pesticides by ion-interaction reversed-phase high-performance liquid chromatography - Diuron determination in lagoon water [J].
Gennaro, MC ;
Abrigo, C ;
Giacosa, D ;
Rigotti, L ;
Liberatori, A .
JOURNAL OF CHROMATOGRAPHY A, 1995, 718 (01) :81-88
[8]   EVALUATION OF CAPILLARY GAS-CHROMATOGRAPHY FOR THERMOLABILE PHENYLUREA HERBICIDES - COMPARISON OF DIFFERENT COLUMNS INCLUDING FUSED-SILICA [J].
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1981, 208 (02) :217-229
[9]   A COMPARISON OF CHEMICAL AND CULTURAL-CONTROL OF WEEDS IN IRRIGATION DITCHBANKS [J].
GROVER, R ;
SMITH, AE ;
KORVEN, HC .
CANADIAN JOURNAL OF PLANT SCIENCE, 1980, 60 (01) :185-195
[10]   DETERMINATION OF PHENYLUREA PESTICIDES IN WATER BY DERIVATIZATION WITH HEPTAFLUOROBUTYRIC ANHYDRIDE AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
KARG, FPM .