CT versus sonography for monitoring radiofrequency ablation in a porcine liver

被引:128
作者
Cha, CH
Lee, FT [1 ]
Gurney, JM
Markhardt, BK
Warner, TF
Kelcz, F
Mahvi, DM
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Surg, Madison, WI 53792 USA
[3] Univ Wisconsin, Dept Pathol, Madison, WI 53793 USA
关键词
D O I
10.2214/ajr.175.3.1750705
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of this study was to compare CT and sonography for monitoring radiofrequency (RF) lesions in porcine livers. SUBJECTS AND METHODS. RF lesions (n = 12) were created in three pig livers by applying 13 min of current to a multielectrode RF probe with a target temperature of 95 degrees C. Helical unenhanced CT and corresponding axial sonography were performed before ablation, at 2 min, 8 min, and immediately after ablation. Contrast-enhanced CT was performed after ablation. CT scans and sonograms were evaluated by blinded observers for conspicuity of the RF lesion, edge detection (visibility of liver-lesion interface), and artifacts. Hounsfield units were recorded at every time interval, and radiologic-pathologic correlation fur lesion size and configuration was performed. RESULTS. Mean size of RF lesions was 3.03 +/- 0.9 cm, On CT, RF lesions had consistently lower attenuation values than surrounding liver (22.2 H lower than liver at 8 min, p < 0.0001). Echogenicity was variable with sonography (hypoechoic = 59%, hyperechoic = 25%, isoechoic = 16%). Unenhanced CT significantly improved conspicuity, edge detection of RF lesions, and decreased artifacts compared with sonography (p < 0.05). Contrast-enhanced CT improved RF lesion detection. border discrimination. and artifacts compared with sonography (p < 0.05). Unenhanced CT had the best correlation to pathologic size (r = 0.74), followed by contrast-enhanced CT (r = 0.72) and sonography (r = 0.56). Contrast-enhanced CT bust correlated with lesion shape, but slightly overestimated size because of areas of ischemia peripheral to the RF lesion. CONCLUSION. In this animal model, unenhanced CT was an effective way to monitor RF ablation compared with sonography because of increased lesion discrimination, reproducible decreased attenuation during ablation, and improved correlation to pathologic size.
引用
收藏
页码:705 / 711
页数:7
相关论文
共 25 条
[1]   MR monitoring of MR-guided radiofrequency thermal ablation of normal liver in an animal model [J].
Boaz, TL ;
Lewin, JS ;
Chung, YC ;
Duerk, JL ;
Clampitt, ME ;
Haaga, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :64-69
[2]  
BRIDBORD K, 1989, CANCER DETECT PREV, V14, P191
[3]   Laparoscopically guided bipolar radiofrequency ablation of areas of porcine liver [J].
Curley, SA ;
Davidson, BS ;
Fleming, RY ;
Izzo, F ;
Stephens, LC ;
Tinkey, P ;
Cromeens, D .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (07) :729-733
[4]   Radiofrequency ablation of unresectable primary and metastatic hepatic malignancies - Results in 123 patients [J].
Curley, SA ;
Izzo, F ;
Delrio, P ;
Ellis, LM ;
Granchi, J ;
Vallone, P ;
Fiore, F ;
Pignata, S ;
Daniele, B ;
Cremona, F .
ANNALS OF SURGERY, 1999, 230 (01) :1-8
[5]   Real-time CT fluoroscopy: Evolution of an interventional tool [J].
Daly, B ;
Templeton, PA .
RADIOLOGY, 1999, 211 (02) :309-315
[6]  
HUGHES K, 1989, SURG CLIN N AM, V69, P339
[7]  
HUGHES KS, 1988, SURGERY, V103, P278
[8]  
KANE RA, 1997, RADIOLOGY, V205, P201
[9]   Hepatic cryosurgery for liver metastases - Long-term follow-up [J].
Korpan, NN .
ANNALS OF SURGERY, 1997, 225 (02) :193-201
[10]   Hepatic cryosurgery with intraoperative US guidance [J].
Lee, FT ;
Mahvi, DM ;
Chosy, SG ;
Onik, GM ;
Wong, WS ;
Littrup, PJ ;
Scanlan, KA .
RADIOLOGY, 1997, 202 (03) :624-632