Sample preparation for photometric determination of histamine in foodstuffs compared with capillary electrophoresis

被引:9
作者
Mahendradatta, M
Schwedt, G
机构
[1] Univ Clausthal, Inst Anorgan & Anlayt Chem Techn, D-38678 Clausthal Zellerfeld, Germany
[2] Hasanuddin Univ, Fac Agr, Dept Agr Prod Proc, Ujung Pandang 90245, Indonesia
来源
ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG A-FOOD RESEARCH AND TECHNOLOGY | 1998年 / 206卷 / 04期
关键词
histamine; capillary electrophoresis; photometric determination; liquid liquid extraction; solid phase extraction;
D O I
10.1007/s002170050252
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
To determine levels of histamine, two methods were used, photometry in conjunction with two sample clean-up procedures, and capillary zone electrophoresis (CZE). The two sample clean-up procedures used were liquid liquid extraction (LLE) with n-butanol and solid phase extraction (SPE). Using CZE, the separation of histamine from the matrix was good. The other method, photometry, represents a classic and simple method, that can be employed for in situ measurement of histamine. We found that it was necessary to clean up the samples prior to photometry; if this was not done, the recorded levels of histamine were higher than those determined by CZE. In order to determine levels of histamine. both of these rapid tests were applied to ten different foodstuffs. The levels of histamine measured using photometry following either LLE or SPE were compared. The results indicated that photometry is a suitable method for the measurement of histamine, although the sample solutions have to be purified by either LLE or SPE. Samples do not need to be cleaned up before CZE because there is no interference between histamine and attendant material. Both sample clean-up procedures were applied to the following foodstuffs: tomatoes, sauerkraut, tuna, leaf spinach, cream spinach, white wine and mackerel. The differences of the measured values vary between 3% and 18% for LLE and 6% and 27% for SPE. For the other foodstuffs, such as beef, beer and nonalcoholic beer, only one sample clean-up procedure is suitable. LLE used for beef and beer leads to differences in measured levels of histamine between 18% and 50%, respectively, whereas SPE used for non-alcoholic beer leads to differences of 20%.
引用
收藏
页码:246 / 250
页数:5
相关论文
共 10 条
[1]  
ASKAR A, 1986, BIOGENE ANIME LEBENS
[2]   HIGH-PRESSURE LIQUID-CHROMATOGRAPHY DETERMINATION OF HISTAMINE IN FISH [J].
GOUYGOU, JP ;
SINQUIN, C ;
DURAND, P .
JOURNAL OF FOOD SCIENCE, 1987, 52 (04) :925-927
[3]   SELECTIVE DETERMINATION OF HISTAMINE BY FLOW-INJECTION ANALYSIS [J].
HUNGERFORD, JM ;
WALKER, KD ;
WEKELL, MM ;
LAROSE, JE ;
THROM, HR .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :1971-1976
[4]  
Krueger C., 1995, Archiv fuer Lebensmittelhygiene, V46, P115
[5]  
Mahendradatta M, 1996, DEUT LEBENSM-RUNDSCH, V92, P218
[6]  
MOPPER B, 1994, J AOAC INT, V77, P881
[7]   HISTAMINE AND TYRAMINE CONTENT OF MEAT-PRODUCTS [J].
RICE, S ;
EITENMILLER, RR ;
KOEHLER, PE .
JOURNAL OF MILK AND FOOD TECHNOLOGY, 1975, 38 (05) :256-258
[8]  
TAYLOR SL, 1977, J FOOD SCI, V42, P1584, DOI 10.1111/j.1365-2621.1977.tb08431.x
[9]  
TAYLOR SL, 1988, FOOD TECHNOL-CHICAGO, V42, P94
[10]  
WURDIG G., 1989, HDB LEBENSMITTELTECH