Layer-by-layer construction of enzyme multilayers on an electrode for the preparation of glucose and lactate sensors: Elimination of ascorbate interference by means of an ascorbate oxidase multilayer

被引:156
作者
Anzai, J [1 ]
Takeshita, H [1 ]
Kobayashi, Y [1 ]
Osa, T [1 ]
Hoshi, T [1 ]
机构
[1] Tohoku Univ, Fac Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9808578, Japan
关键词
D O I
10.1021/ac970536b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A layer-by-layer structure of enzyme multilayers composed of glucose oxidase (GOx) or lactate oxidase (LOx) and ascorbate oxidase (AOx) was prepared on the surface of a platinum electrode, The amperometric response to glucose or lactate was studied in the presence of ascorbic acid as a possible interference, An alternating and repeated deposition of avidin and the biotin-labeled enzymes resulted in the layer-by-layer structure of GOx/AOx and LOx/AOx multilayers. Optical and gravimetric measurements based on an ultraviolet-visible absorption spectroscopy and a quartz crystal microbalance revealed that the enzyme multilayers thus prepared consist of monomolecular layers of the proteins, The GOx/AOx and LOx/AOx enzyme multilayers were useful to eliminate ascorbic acid interference in the glucose and lactate biosensors, because ascorbic acid can be converted to an electrochemically inert form, dehydroascorbic acid, before being oxidized directly on the Pt electrode. Thus, the GOx/AOx or LOx/AOx multilayer-modified biosensors can be used to determine the normal blood level of glucose (5 mM) and lactate (1 mM) in the presence of a physiological level of ascorbic acid (0.1 mM). The effects of the number of the AOx layers and geometry of the enzyme layers in the multilayer on the performance characteristics of the biosensors are discussed.
引用
收藏
页码:811 / 817
页数:7
相关论文
共 35 条
[21]   SIMULTANEOUS ENZYMATIC DETERMINATION OF GLUCOSE AND ASCORBIC-ACID USING FLOW-INJECTION AMPEROMETRY [J].
MATUSZEWSKI, W ;
TROJANOWICZ, M ;
ILCHEVA, L .
ELECTROANALYSIS, 1990, 2 (02) :147-153
[22]   REFINED CRYSTAL-STRUCTURE OF ASCORBATE OXIDASE AT 1.9 A RESOLUTION [J].
MESSERSCHMIDT, A ;
LADENSTEIN, R ;
HUBER, R ;
BOLOGNESI, M ;
AVIGLIANO, L ;
PETRUZZELLI, R ;
ROSSI, A ;
FINAZZIAGRO, A .
JOURNAL OF MOLECULAR BIOLOGY, 1992, 224 (01) :179-205
[23]   PIEZOELECTRIC RESONATOR AS A CHEMICAL AND BIOCHEMICAL SENSING DEVICE [J].
MURAMATSU, H ;
SUDA, M ;
ATAKA, T ;
SEKI, A ;
TAMIYA, E ;
KARUBE, I .
SENSORS AND ACTUATORS A-PHYSICAL, 1990, 21 (1-3) :362-368
[24]   AMPEROMETRIC GLUCOSE BIOSENSOR MANUFACTURED BY A PRINTING TECHNIQUE [J].
NAGATA, R ;
CLARK, SA ;
YOKOYAMA, K ;
TAMIYA, E ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1995, 304 (02) :157-164
[25]   A NEW TYPE OF ENZYME ELECTRODE - THE ASCORBIC-ACID ELIMINATOR ELECTRODE [J].
NAGY, G ;
RICE, ME ;
ADAMS, RN .
LIFE SCIENCES, 1982, 31 (23) :2611-2616
[26]   PURIFICATION AND PROPERTIES OF ASCORBATE OXIDASE FROM CUCUMBER [J].
NAKAMURA, T ;
MAKINO, N ;
OGURA, Y .
JOURNAL OF BIOCHEMISTRY, 1968, 64 (02) :189-&
[27]   Catalytic oxidation of ascorbic acid by some ferrocene derivative mediators at the glassy carbon electrode. Application to the voltammetric resolution of ascorbic acid and dopamine in the same sample [J].
PournaghiAzar, MH ;
Ojani, R .
TALANTA, 1995, 42 (12) :1839-1848
[28]   CAN CONTINUOUS GLUCOSE MONITORING BE USED FOR THE TREATMENT OF DIABETES [J].
REACH, G ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :A381-A386
[29]   ELECTROPOLYMERIZED 1,2-DIAMINOBENZENE AS A MEANS TO PREVENT INTERFERENCES AND FOULING AND TO STABILIZE IMMOBILIZED ENZYME IN ELECTROCHEMICAL BIOSENSORS [J].
SASSO, SV ;
PIERCE, RJ ;
WALLA, R ;
YACYNYCH, AM .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1111-1117
[30]   ION-EXCHANGE SELECTIVITY OF NAFION FILMS ON ELECTRODE SURFACES [J].
SZENTIRMAY, MN ;
MARTIN, CR .
ANALYTICAL CHEMISTRY, 1984, 56 (11) :1898-1902