Minimum local analgesic concentration of extradural bupivacaine increases with progression of labour

被引:85
作者
Capogna, G
Celleno, D
Lyons, G
Columb, M
Fusco, P
机构
[1] Fatebenefratelli Gen Hosp, Dept Anaesthesiol, I-00186 Rome, Italy
[2] Fatebenefratelli Gen Hosp, Dept Obstet & Gynaecol, I-00186 Rome, Italy
[3] St James Univ Hosp, Leeds LS9 7TF, W Yorkshire, England
[4] Withington Hosp, Intens Care Unit, Manchester M20 2LR, Lancs, England
关键词
pregnancy; analgesia; obstetric; analgesic techniques; extradural; anaesthetics local; bupivacaine;
D O I
10.1093/bja/80.1.11
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We have used the technique of double-blind sequential allocation to quantify the minimum local analgesic concentration (MLAC) of extradural bupivacaine for women in early (median cervical dilatation 2 cm) and late (median cervical dilatation 5 cm) labour. The first bolus was 20 mi of the bupivacaine test solution. The concentration was determined by the response of the previous woman to a higher or lower concentration of bupivacaine according to up and down sequential allocation. Efficacy was assessed using a 100-mm visual analogue pain score (VAPS). The test solution had to achieve a VAPS of 10 mm or less to be judged effective. In early labour, the MLAC of bupivacaine was 0.048% w/v (95% confidence intervals (CI) 0.037-0.058% w/v), and 0.140% w/v (95% CI 0.132-0.150% w/v) in the late group. The MLAC of bupivacaine in late labour was greater by a factor of 2.9 (95% CI 2.7-3.2) compared with the MLAC in early labour (P < 0.0001, 95% CI difference 0.08-0.11). We conclude that advancing labour requires an increased concentration of extradural bupivacaine for pain relief.
引用
收藏
页码:11 / 13
页数:3
相关论文
共 12 条
  • [1] Altman DG, 1991, PRACTICAL STAT MED R, P212
  • [2] ARMITAGE P, 1994, STAT METHODS MED RES, P136
  • [3] PERIPHERAL MECHANISMS AND PATHWAYS OF PARTURITION PAIN
    BONICA, JJ
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1979, 51 : S3 - S9
  • [4] BREEN TW, 1993, ANESTH ANALG, V77, P919
  • [5] DETERMINATION OF THE MINIMUM LOCAL ANALGESIC CONCENTRATIONS OF EPIDURAL BUPIVACAINE AND LIDOCAINE IN LABOR
    COLUMB, MO
    LYONS, G
    [J]. ANESTHESIA AND ANALGESIA, 1995, 81 (04) : 833 - 837
  • [6] DEJONG RH, 1994, LOCAL ANESTHETICS, P74
  • [7] Dixon WJ, 1983, INTRO STAT ANAL, P428
  • [8] Extradural pain relief in labour: Bupivacaine sparing by extradural fentanyl is dose dependent
    Lyons, G
    Columb, M
    Hawthorne, L
    Dresner, M
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1997, 78 (05) : 493 - 497
  • [9] MATHER LE, 1994, ANAESTHESIA, P132
  • [10] INTRATHECAL MORPHINE AS SOLE ANALGESIC DURING LABOR
    SCOTT, PV
    BOWEN, FE
    CARTWRIGHT, P
    RAO, BCM
    DEELEY, D
    WOTHERSPOON, HG
    SUMREIN, IMA
    [J]. BRITISH MEDICAL JOURNAL, 1980, 281 (6236) : 351 - 353