Porous Tantalum and Titanium in Orthopedics: A Review

被引:160
作者
Han, Qing [1 ]
Wang, Chenyu [1 ]
Chen, Hao [1 ]
Zhao, Xue [2 ]
Wang, Jincheng [1 ]
机构
[1] Second Hosp Jilin Univ, Dept Orthoped, Changchun 130000, Jilin, Peoples R China
[2] First Hosp Jilin Univ, Dept Endocrine & Metab, Changchun 130000, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
porous metal; porous structure; titanium; tantalum; orthopedic application; TOTAL KNEE ARTHROPLASTY; TRABECULAR METAL CONES; TOTAL HIP-ARTHROPLASTY; TOTAL SHOULDER ARTHROPLASTY; ANTERIOR CERVICAL CORPECTOMY; ACETABULAR REVISION SURGERY; MINIMAL SURFACE-STRUCTURES; LUMBAR INTERBODY FUSION; BONE-MINERAL DENSITY; THAN; 60; YEARS;
D O I
10.1021/acsbiomaterials.9b00493
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
082905 [生物质能源与材料]; 100103 [病原生物学];
摘要
Porous metal is metal with special porous structures, which can offer high biocompatibility and low Young's modulus to satisfy the need for orthopedic applications. Titanium and tantalum are the most widely used porous metals in orthopedics due to their excellent biomechanical properties and biocompatibility. Porous titanium and tantalum have been studied and applied for a long history until now. Here in this review, various manufacturing methods of titanium and tantalum porous metals are introduced. Application of these porous metals in different parts of the body are summarized, and strengths and weaknesses of these porous metal implants in clinical practice are discussed frankly for future improvement from the viewpoint of orthopedic surgeons. Then according to the requirements from clinics, progress in research for clinical use is illustrated in four aspects. Various creative designs of microporous and functionally gradient structure, surface modification, and functional compound systems of porous metal are exhibited as reference for future research. Finally, the directions of orthopedic porous metal development were proposed from the clinical view based on the rapid progress of additive manufacturing. Controllable design of both macroscopic anatomical bionic shape and microscopic functional bionic gradient porous metal, which could meet the rigorous mechanical demand of bone reconstruction, should be developed as the focus. The modification of a porous metal surface and construction of a functional porous metal compound system, empowering stronger cell proliferation and antimicrobial and antineoplastic property to the porous metal implant, also should be taken into consideration.
引用
收藏
页码:5798 / 5824
页数:53
相关论文
共 235 条
[1]
Tantalum foam made with sucrose as a space holder [J].
Adamek, Grzegorz ;
Jakubowicz, Jaroslaw .
INTERNATIONAL JOURNAL OF REFRACTORY METALS & HARD MATERIALS, 2015, 53 :51-55
[2]
Compressive characteristics of radially graded porosity scaffolds architectured with minimal surfaces [J].
Afshar, M. ;
Anaraki, A. Pourkamali ;
Montazerian, H. .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2018, 92 :254-267
[3]
Mechanical behavior of regular open-cell porous biomaterials made of diamond lattice unit cells [J].
Ahmadi, S. M. ;
Campoli, G. ;
Yavari, S. Amin ;
Sajadi, B. ;
Wauthle, R. ;
Schrooten, J. ;
Weinans, H. ;
Zadpoor, A. A. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 34 :106-115
[4]
Additively Manufactured Open-Cell Porous Biomaterials Made from Six Different Space-Filling Unit Cells: The Mechanical and Morphological Properties [J].
Ahmadi, Seyed Mohammad ;
Yavari, Saber Amin ;
Wauthle, Ruebn ;
Pouran, Behdad ;
Schrooten, Jan ;
Weinans, Harrie ;
Zadpoor, Amir A. .
MATERIALS, 2015, 8 (04) :1871-1896
[5]
Poor outcomes of fusion with Trabecular Metal implants after failed total ankle replacement: Early results in 11 patients [J].
Aubret, S. ;
Merlini, L. ;
Fessy, M. ;
Besse, J. -L. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (02) :231-237
[6]
Simultaneous Delivery of Multiple Antibacterial Agents from Additively Manufactured Porous Biomaterials to Fully Eradicate Planktonic and Adherent Staphylococcus aureus [J].
Bakhshandeh, S. ;
Karaji, Z. Gorgin ;
Lietaert, K. ;
Fluit, A. C. ;
Boel, C. H. E. ;
Vogely, H. C. ;
Vermonden, T. ;
Hennink, W. E. ;
Weinans, H. ;
Zadpoor, A. A. ;
Yavari, S. Amin .
ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (31) :25691-25699
[7]
Porous tantalum structures for bone implants: Fabrication, mechanical and in vitro biological properties [J].
Balla, Vamsi Krishna ;
Bodhak, Subhadip ;
Bose, Susmita ;
Bandyopadhyay, Amit .
ACTA BIOMATERIALIA, 2010, 6 (08) :3349-3359
[8]
In Vivo Response of Laser Processed Porous Titanium Implants for Load-Bearing Implants [J].
Bandyopadhyay, Amit ;
Shivaram, Anish ;
Tarafder, Solaiman ;
Sahasrabudhe, Himanshu ;
Banerjee, Dishary ;
Bose, Susmita .
ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (01) :249-260
[9]
Systematic review on outcomes of acetabular revisions with highly-porous metals [J].
Banerjee, Samik ;
Issa, Kimona ;
Kapadia, Bhaveen H. ;
Pivec, Robert ;
Khanuja, Harpal S. ;
Mont, Michael A. .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) :689-702
[10]
Banerjee S, 2013, HIP INT, V23, P509, DOI 10.530/hipint.5000064