New extraction method for the analysis of linear alkylbenzene sulfonates in marine organisms -: Pressurized liquid extraction versus Soxhlet extraction
被引:15
作者:
Alvarez-Muñoz, D
论文数: 0引用数: 0
h-index: 0
机构:
Univ Cadiz, Fac Ciencias Mar & Ambientales, Dept Quim Fis, Cadiz 11510, SpainUniv Cadiz, Fac Ciencias Mar & Ambientales, Dept Quim Fis, Cadiz 11510, Spain
Alvarez-Muñoz, D
[1
]
Sáez, M
论文数: 0引用数: 0
h-index: 0
机构:
Univ Cadiz, Fac Ciencias Mar & Ambientales, Dept Quim Fis, Cadiz 11510, SpainUniv Cadiz, Fac Ciencias Mar & Ambientales, Dept Quim Fis, Cadiz 11510, Spain
Sáez, M
[1
]
Lara-Martín, PA
论文数: 0引用数: 0
h-index: 0
机构:
Univ Cadiz, Fac Ciencias Mar & Ambientales, Dept Quim Fis, Cadiz 11510, SpainUniv Cadiz, Fac Ciencias Mar & Ambientales, Dept Quim Fis, Cadiz 11510, Spain
Lara-Martín, PA
[1
]
Gómez-Parra, A
论文数: 0引用数: 0
h-index: 0
机构:
Univ Cadiz, Fac Ciencias Mar & Ambientales, Dept Quim Fis, Cadiz 11510, SpainUniv Cadiz, Fac Ciencias Mar & Ambientales, Dept Quim Fis, Cadiz 11510, Spain
Gómez-Parra, A
[1
]
González-Mazo, E
论文数: 0引用数: 0
h-index: 0
机构:
Univ Cadiz, Fac Ciencias Mar & Ambientales, Dept Quim Fis, Cadiz 11510, SpainUniv Cadiz, Fac Ciencias Mar & Ambientales, Dept Quim Fis, Cadiz 11510, Spain
González-Mazo, E
[1
]
机构:
[1] Univ Cadiz, Fac Ciencias Mar & Ambientales, Dept Quim Fis, Cadiz 11510, Spain
A new method has been developed for the determination of linear alkylbenzene sulfonates (LAS) from various marine organisms, and compared with Soxhlet extraction. The technique applied includes the use of pressurized liquid extraction (PLE) for the extraction stage, preconcentration of the samples, purification by solid-phase extraction (SPE) and analysis by liquid chromatography with fluorescence detection. The spiked concentrations were added to the samples (wet mass of the organisms: Solea senegalensis and Ruditapes semidecussatus), which were homogenized and agitated continuously for 25 h. The samples were extracted by pressurized hot solvent extraction using two different extraction temperatures (100 and 150degreesC) and by traditional Soxhlet extraction. The best recoveries were obtained employing pressurized hot solvent extraction at 100degreesC and varied in the range from 66.1 to 101.3% with a standard deviation of between 2 and 13. Detection limit was between 5 and 15 mug kg(-1) wet mass using HPLC-fluorescence detection. The analytical method developed in this paper has been applied for LAS determination in samples from a Flow-through exposure system with the objective of measuring the bioconcentration of this surfactant. (C) 2004 Elsevier B.V. All rights reserved.