A novel method for applying cavity ring-down spectroscopy in the liquid phase, compatible with LC analyses, is presented. The core of the setup is a home-built cavity ring-down flow cell (cell volume 12 muL) that is constructed using a silicon rubber spacer, which is clamped leak-tight between two high-reflectivity mirrors. The mirrors are in direct contact with the liquid flow, which provides for a small path length and short ring-down times. Inside the cavity there are no windows, reflection losses, or Brewster angles to be considered. Due to the small size of the presented cavity geometry, the setup can be implemented in conventional-size LC apparatuses. With a flow injection setup, a detection limit of 2.5 nM was obtained for Crystal Violet in ethanol, and the linear dynamic range of the system is at least 2 orders of magnitude. The method has the potential to become a powerful alternative for commercial LC UV/visible absorbance detectors.
引用
收藏
页码:1188 / 1191
页数:4
相关论文
共 11 条
[1]   Cavity ring-down spectroscopy: Experimental schemes and applications [J].
Berden, G ;
Peeters, R ;
Meijer, G .
INTERNATIONAL REVIEWS IN PHYSICAL CHEMISTRY, 2000, 19 (04) :565-607
[2]   Detector cell based on plastic liquid-core waveguides suitable for aqueous solutions: one-to-two decades improved detection limits in conventional-size column liquid chromatography with absorption detection [J].
Gooijer, C ;
Hoornweg, GP ;
de Beer, T ;
Bader, A ;
van Iperen, DJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1998, 824 (01) :1-5
[3]   Direct monitoring of absorption in solution by cavity ring-down spectroscopy [J].
Hallock, AJ ;
Berman, ESF ;
Zare, RN .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1741-1743
[4]   CAVITY RING-DOWN OPTICAL SPECTROMETER FOR ABSORPTION-MEASUREMENTS USING PULSED LASER SOURCES [J].
OKEEFE, A ;
DEACON, DAG .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (12) :2544-2551
[5]   Ultrasensitive surface spectroscopy with a miniature optical resonator [J].
Pipino, ACR .
PHYSICAL REVIEW LETTERS, 1999, 83 (15) :3093-3096
[6]   Evanescent wave cavity ring-down spectroscopy with a total-internal-reflection minicavity [J].
Pipino, ACR ;
Hudgens, JW ;
Huie, RE .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (08) :2978-2989
[7]   SPLIT-PULSE LASER METHOD FOR MEASURING ATTENUATION COEFFICIENTS OF TRANSPARENT LIQUIDS - APPLICATION TO DEIONIZED FILTERED WATER IN VISIBLE REGION [J].
QUERRY, MR ;
CARY, PG ;
WARING, RC .
APPLIED OPTICS, 1978, 17 (22) :3587-3592
[8]   Adsorption of crystal violet to the silica-water interface monitored by evanescent wave cavity ring-down spectroscopy [J].
Shaw, AM ;
Hannon, TE ;
Li, FP ;
Zare, RN .
JOURNAL OF PHYSICAL CHEMISTRY B, 2003, 107 (29) :7070-7075
[9]   Cavity ring-down spectroscopy as a detector for liquid chromatography [J].
Snyder, KL ;
Zare, RN .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3086-3091
[10]   Application of liquid waveguide to Raman spectroscopy in aqueous solution [J].
Song, L ;
Liu, SY ;
Zhelyaskov, V ;
El-Sayed, MA .
APPLIED SPECTROSCOPY, 1998, 52 (10) :1364-1367