Advanced External Shading Device to Maximize Visual and View Performance

被引:51
作者
Kim, Jeong Tai [2 ]
Kim, Gon [1 ]
机构
[1] Kangwon Natl Univ, Div Architecture, Chunchon 200701, Gangwon Do, South Korea
[2] Kyung Hee Univ, Dept Architectural Engn, Yongin 446701, Gyeonggi Do, South Korea
关键词
Shading device; Shading effect; Energy performance; View; Daylighting; Simulation analysis; DAYLIGHT; IMPACT;
D O I
10.1177/1420326X09358001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Controlling or avoiding direct sun beam shining into the interior is a key criterion for consideration in most architectural daylighting designs. This treatment is mainly intended to attenuate the adverse glare and contrast associated with direct sunlight and to lessen the negative contribution of direct sunlight on the cooling load. Window shades are commonly used in Korea to reduce heat gains in the form of direct beam radiation, particularly in summer. Very often they consist of non-movable structures, such as overhangs, vertical fins or composition of both, forming eggcrate-type systems, and ideally should be designed by incorporating these methods. One of the simplest sunlighting controls is Venetian blind. It plays a role in excluding direct sunlight but reflecting light to rear interior, while still allowing a view to exterior. The blinds also go far toward improving uniformity in illuminance. External shading devices are much more effective than internal shading devices. However, it is not popular because of cost, maintenance, and esthetic reasons. We developed an experimental configuration of external shading device, providing better performance of shading and view. A series of simulations and measurements have verified the differentiated advantages in illumination and building energy consumption by using this system.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 13 条
[1]   A methodology for simulation of daylight room illuminance distribution and light dimming for a room with a controlled shading device [J].
Athienitis, AK ;
Tzempelikos, A .
SOLAR ENERGY, 2002, 72 (04) :271-281
[2]   Effect of fixed horizontal louver shading devices on thermal performance of building by TRNSYS simulation [J].
Datta, G .
RENEWABLE ENERGY, 2001, 23 (3-4) :497-507
[3]  
DUBOIS MC, 2003, LIGHTING RES TECHNOL, V359, P61
[4]   Simple tool to evaluate the impact of daylight on building energy consumption [J].
Hviid, Christian Anker ;
Nielsen, Toke Rammer ;
Svendsen, Svend .
SOLAR ENERGY, 2008, 82 (09) :787-798
[5]   Complex fenestration systems: towards product ratings for indoor environment quality [J].
Laouadi, A. ;
Parekh, A. .
LIGHTING RESEARCH & TECHNOLOGY, 2007, 39 (02) :109-122
[6]  
Reinhart C F., 2003, Lighting Research and Technology, V35, P243, DOI [DOI 10.1191/1365782803LI064OA, 10.1191/1365782803li064oa]
[7]   Summertime performance of an automated lighting and blinds control system [J].
Roche, L. .
Lighting Research and Technology, 2002, 34 (01) :11-27
[8]   Theoretical and experimental analysis of daylight performance for various shading systems [J].
Tsangrassoulis, A ;
Santamouris, M ;
Asimakopoulos, D .
ENERGY AND BUILDINGS, 1996, 24 (03) :223-230
[9]   View and discomfort glare from windows [J].
Tuaycharoen, N. ;
Tregenza, P. R. .
LIGHTING RESEARCH & TECHNOLOGY, 2007, 39 (02) :185-200
[10]   The impact of shading design and control on building cooling and lighting demand [J].
Tzempelikos, Athanassios ;
Athienitis, Andreas K. .
SOLAR ENERGY, 2007, 81 (03) :369-382