Differential electrolytic potentiometry, a detector in flow injection analysis for oxidation-reduction reactions

被引:9
作者
Abulkibash, AMS [1 ]
Koken, ME [1 ]
Khaled, LM [1 ]
Sultan, SM [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Chem, Dhahran 31261, Saudi Arabia
关键词
DEP; FIA; vitamin C; cerium(IV);
D O I
10.1016/S0039-9140(00)00487-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time, differential electropotentiometry (DEP) is coupled with the flow injection analysis (FIA) technique for detection of oxidation-reduction reactions, and is utilized for quantitative determination of vitamin C in pharmaceutical preparations using 1.0 x 10(-3)-M cerium(IV) in 0.50-M sulfuric acid as carrier. Two similar platinum electrodes were employed and polarized by a constant current. Optimization by the univariate method was carried out and the optimum conditions for current density, flow rate, sample size and concentration of sulfuric acid were 4 mA, 0.93 ml min(-1), 140 mul and 0.25 M, respectively. Vitamin C was determined in the concentration range 100-300 ppm with 0.9987 correlation coefficient and 1.9 standard deviation. The method was applied to the determination of vitamin C in pharmaceutical preparations and no excipient was found to pose any interference thus rendering the method suitable for determination of the drug in pharmaceutical preparations. The accuracy of the method was determined by comparison with the BP standard method. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1139 / 1142
页数:4
相关论文
共 11 条
[1]  
Abdennabi A. M. S., 1986, AJSE, V12, P82
[2]   DIFFERENTIAL ELECTROLYTIC POTENTIOMETRY WITH PERIODIC POLARIZATION .27. DIRECT AND MARK-SPACE BIASED PERIODIC POLARIZATION IN SUBSTITUTION, ADDITION AND OXIDATION TITRIMETRY WITH DIBROMINE IN ANHYDROUS ACETIC-ACID [J].
ABDENNABI, AMS ;
BISHOP, E .
ANALYST, 1983, 108 (1291) :1227-1234
[3]   DIFFERENTIAL ELECTROLYTIC POTENTIOMETRY .26. DIRECT POLARIZATION IN ACID-BASE TITRIMETRY IN TOLUENE-METHANOL MIXTURES [J].
ABDENNABI, AMS ;
BISHOP, E .
ANALYST, 1983, 108 (1282) :71-75
[4]   DIFFERENTIAL ELECTROLYTIC POTENTIOMETRY WITH PERIODIC POLARIZATION .25. DIRECT AND MARK-SPACE BIASED PERIODIC CURRENT POLARIZATION IN ACID-BASE TITRIMETRY IN ACETIC ANHYDRIDE-ACETIC ACID [J].
ABDENNABI, AMS ;
BISHOP, E .
ANALYST, 1982, 107 (1278) :1032-1039
[5]   Differential electrolytic potentiometry, a detector in flow injection analysis for precipitation reactions [J].
Abdennabi, AMS ;
Koken, ME .
TALANTA, 1998, 46 (04) :639-646
[6]   DIFFERENTIAL ELECTROLYTIC POTENTIOMETRY .14. EXAMINATION OF ELECTRODE PARAMETERS + ELECTRODE SYSTEMS IN ACID-BASE TITRIMETRY [J].
BISHOP, E ;
SHORT, GD .
ANALYST, 1964, 89 (105) :415-&
[7]   DIFFERENTIAL ELECTROLYTIC POTENTIOMETRY WITH PERIODIC POLARIZATION .29. PRECIPITATION AND COMPLEXATION TITRATIONS IN ANHYDROUS ACETIC-ACID [J].
BISHOP, E ;
ABDENNABI, AMS .
ANALYST, 1983, 108 (1292) :1349-1356
[8]   DIFFERENTIAL ELECTROLYTIC POTENTIOMETRY .5. PRECISION AND ACCURACY OF APPLICATIONS TO ARGENTIMETRY [J].
BISHOP, E ;
DHANESHW.RG .
ANALYST, 1962, 87 (1032) :207-&
[9]   DIFFERENTIAL ELECTROLYTIC POTENTIOMETRY .6. PRECISION AND ACCURACY OF APPLICATIONS TO ACID-BASE TITRATIONS WITH ANTIMONY ELECTRODES [J].
BISHOP, E ;
SHORT, GD .
ANALYST, 1962, 87 (1035) :467-&
[10]   DIFFERENTIAL ELECTROLYTIC POTENTIOMETRY .7. INTERPRETATION OF CURRENT-POTENTIAL-TEMPERATURE RELATIONSHIPS OF ANTIMONY ELECTRODES IN NEUTRAL SOLUTION [J].
SHORT, GD ;
BISHOP, E .
ANALYST, 1962, 87 (1038) :724-&