Development and characterization of an electrospray ionization ion trap linear time-of-flight mass spectrometer

被引:24
作者
Purves, RW [1 ]
Li, L [1 ]
机构
[1] UNIV ALBERTA,DEPT CHEM,EDMONTON,AB T6G 2G2,CANADA
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1016/S1044-0305(97)00146-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
On-line analysis of compounds from solution has been greatly facilitated by the advent of electrospray ionization mass spectrometry (ESI-MS). Although quadrupole mass analyzers are most commonly used with ESI at present, time-of-flight (TOF) mass spectrometers offer several potential advantages including high data acquisition rates, which are desirable for fast separation techniques. One method of coupling ESI and TOF uses an ion trap for temporary storage and accumulation of the electrosprayed ions prior to TOF mass analysis. Previous studies have not fully addressed the effects of several key variables on the analytical capabilities of this type of instrument. In this study, the characterization of an ion trap/linear TOF instrument for ESI is described. The behavior of various analytes is divided into two separate groups; each one is found to have its own optimal set of operating conditions. The reasons for the observed differences between groups are explored. Issues relevant to mass resolution, sensitivity, mass range, mass-to-charge ratio discrimination, and mass measurement accuracy are addressed. Finally, it is suggested that the analytical capability of this type of instrument could be significantly improved by changing the ion optics from the existing focusing lenses to a rf-only quadrupole lens. (C) 1997 American Society for Mass Spectrometry.
引用
收藏
页码:1085 / 1093
页数:9
相关论文
共 23 条
[1]   Detection of fast capillary electrophoresis peptide and protein separations using electrospray ionization with a time-of-flight mass spectrometer [J].
Banks, JF ;
Dresch, T .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1480-1485
[2]   TIME-OF-FLIGHT MASS-SPECTROMETRY WITH AN ELECTROSPRAY ION-BEAM [J].
BOYLE, JG ;
WHITEHOUSE, CM .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2084-2089
[3]  
CHAMBERS DM, 1995, P 43 ASMS C MASS SPE, P1138
[4]   Effect of ion-molecule collisions in the vacuum chamber of an electrospray time-of-flight mass spectrometer on mass spectra of proteins [J].
Chernushevich, IV ;
Verentchikov, AN ;
Ens, W ;
Standing, KG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (04) :342-349
[5]   THE DESIGN AND PERFORMANCE OF AN ION-TRAP STORAGE REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER [J].
CHIEN, BM ;
MICHAEL, SM ;
LUBMAN, DM .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 131 :149-179
[6]  
Dodonov A.F., 1991, 12 IMSC, P153
[7]   COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :398-408
[8]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[9]  
KRUTCHINSKY AN, 1995, P 43 ASMS C MASS SPE, P126
[10]   THE DESIGN OF AN ATMOSPHERIC-PRESSURE IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETER USING A BEAM DEFLECTION METHOD [J].
MA, C ;
MICHAEL, SM ;
CHIEN, MT ;
ZHU, JZ ;
LUBMAN, DM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :139-148