Evaluation of an automated system for the collection of packed RBCs, platelets, and plasma

被引:35
作者
Elfath, MD
Whitley, P
Jacobson, MS
Cranfill-Hupp, K
Kemp, DM
McNeil, D
Sawyer, S
Bell-Dize, S
Gorlin, JB
Kevy, SV
McAteer, MJ
机构
[1] Gambro BCT Inc, Lakewood, CO 80215 USA
[2] Amer Red Cross, Norfolk, VA USA
[3] Eastern Virginia Med Sch, Dept Pathol, Norfolk, VA 23501 USA
[4] Childrens Hosp, Boston, MA 02115 USA
关键词
D O I
10.1046/j.1537-2995.2000.40101214.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: This study evaluated the quality of WBC-reduced platelets, RBCs, and plasma collected on a new system (Trima, Gambro BCT) designed to automate the collection of all blood components. The study also evaluated donor safety and suitability of these components for transfusion. STUDY DESIGN AND METHODS: In Phase I, the quality of the components collected on the new system was evaluated by standard in vitro and in vivo testing methods. Results were compared to those from control components collected by currently approved standard methods. In Phase II, additional collections were performed to evaluate the acceptability of the new system and the safety of platelets collected. RESULTS: In vivo 24-hour RBC recovery was 76.8 +/- 3.1 percent for the test RBC units and 77.1 +/- 4.4 percent recovery for whole-blood (control) RBCs. The differences between test and control platelet results in the in vivo and in vitro assays were not clinically significant. Plasma clotting factors and fibrinogen levels met international standards. The system was well accepted by donors, and no major adverse donor reactions were reported for the 68 procedures performed. No problems were reported with transfusing the blood components collected. CONCLUSION: Blood components collected with the Trima are equivalent to currently available components, and they meet the applicable regulatory standards. This system provides consistent, standardized components with predictable yields. It provides the option of fully automating the collection of all blood components.
引用
收藏
页码:1214 / 1222
页数:9
相关论文
共 33 条
[1]  
[Anonymous], 1980, BRIT J HAEMATOL, V45, P659
[2]   TESTING IN THE YEARS AHEAD - NEW PRESSURES AND NEW CONCERNS [J].
BOVE, JR .
TRANSFUSION, 1990, 30 (01) :63-67
[3]   CAN (SHOULD) APHERESIS SUPPLANT WHOLE-BLOOD COLLECTION [J].
CIAVARELLA, D .
TRANSFUSION SCIENCE, 1992, 13 (02) :201-205
[4]  
*COUNC EUR PUB, 1999, GUID PREP US QUAL AS
[5]  
DEVERDIE.CH, 1969, VOX SANG, V16, P361
[6]  
Elfath M., 1995, Blood, V86, p545A
[7]   A multicenter evaluation of the routine use of a new white cell-reduction apheresis system for collection of platelets [J].
Fournel, JJ ;
Zingsem, J ;
Riggert, J ;
Muylle, L ;
Muller, N ;
Kohler, M ;
Beaumont, JL ;
Baeten, M ;
Eckstein, R ;
vanWaeg, G .
TRANSFUSION, 1997, 37 (05) :487-492
[8]   EVALUATION OF TECHNETIUM-99M-CHROMIUM-51 POST-TRANSFUSION RECOVERY OF RED-CELLS STORED IN SALINE, ADENINE, GLUCOSE, MANNITOL FOR 42 DAYS [J].
HEATON, WAL ;
KEEGAN, T ;
HOLME, S ;
MOMODA, G .
VOX SANGUINIS, 1989, 57 (01) :37-42
[9]  
HEYMAN MR, 1990, SEMIN ONCOL, V17, P198
[10]   A multi-laboratory evaluation of in vitro platelet assays: the tests for extent of shape change and response to hypotonic shock [J].
Holme, S ;
Moroff, G ;
Murphy, S .
TRANSFUSION, 1998, 38 (01) :31-40