Sensorless freehand 3-D ultrasound using regression of the echo intensity

被引:44
作者
Prager, RW
Gee, AH
Treece, GM
Cash, CJC
Berman, LH
机构
[1] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
[2] Univ Cambridge, Dept Radiol, Cambridge CB2 1PZ, England
关键词
freehand 3-D ultrasound; linear regression; distance measurement; speckle;
D O I
10.1016/S0301-5629(02)00703-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In freehand 3-D ultrasound (US), a position sensor is attached to the probe of a 2-D US machine. The resulting 3-D data permit flexible visualisation and more accurate volume measurement than can be achieved using 2-D B-scans alone; however, the use of the position sensor can be inconvenient for the clinician. The objective is, thus, to replace the sensor with a technique for estimating the probe trajectory based on the B-scan images, themselves. One such technique exists, based on decorrelation algorithms. This paper presents an alternative approach based on linear regression of the echo-envelope intensity signal. A probabilistic analysis of the speckle characteristics of the US signal leads to a linear model, on which the regression algorithm is based. The gradient parameter of this model is shown to be directly related to probe motion. The viability of the new approach is demonstrated through simulations and in vitro and in vivo experiments. (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 14 条
[1]  
Chen JF, 1997, INT J IMAG SYST TECH, V8, P38, DOI 10.1002/(SICI)1098-1098(1997)8:1<38::AID-IMA5>3.0.CO
[2]  
2-U
[3]   MEASUREMENT OF SOFT-TISSUE MOTION USING CORRELATION BETWEEN A-SCANS [J].
DICKINSON, RJ ;
HILL, CR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (03) :263-271
[4]   RANDOM SAMPLE CONSENSUS - A PARADIGM FOR MODEL-FITTING WITH APPLICATIONS TO IMAGE-ANALYSIS AND AUTOMATED CARTOGRAPHY [J].
FISCHLER, MA ;
BOLLES, RC .
COMMUNICATIONS OF THE ACM, 1981, 24 (06) :381-395
[5]   Improved method for determining resolution zones in ultrasound phantoms with spherical simulated lesions [J].
Kofler, JM ;
Madsen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (12) :1667-1676
[6]  
Li M, 1995, U.S. Patent, Patent No. [5,582,173, 5582173]
[7]   Liquid or solid ultrasonically tissue-mimicking materials with very low scatter [J].
Madsen, EL ;
Frank, GR ;
Dong, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (04) :535-542
[8]  
More J. J., 1978, Proceedings of the Biennial Conference on numerical analysis, P105
[9]   Decompression and speckle detection for ultrasound images using the homodyned k-distribution [J].
Prager, RW ;
Gee, AH ;
Treece, GM ;
Berman, LH .
PATTERN RECOGNITION LETTERS, 2003, 24 (4-5) :705-713
[10]  
PRAGER RW, 2001, CUEDFINFENGTR415