Application of nonpolar matrices for the analysis of low molecular weight nonpolar synthetic polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

被引:38
作者
Macha, SF
Limbach, PA [1 ]
Savickas, PJ
机构
[1] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
[2] Dow Chem Co, Analyt Sci Lab, Midland, MI 48674 USA
基金
美国国家科学基金会;
关键词
D O I
10.1016/S1044-0305(00)00137-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of nonpolar matrices for the analysis of low molecular weight nonpolar synthetic polymers using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is demonstrated. Anthracene, pyrene, and acenaphthene were utilized as nonpolar matrices for the analysis of polybutadiene, polyisoprene, and polystyrene samples of various average molecular weights ranging from about 700 to 5000. The standard MALDI-MS approach for the analysis of these types of polymers involves the use of conventional acidic matrices, such as all-trans-retinoic acid, with an additional cationization reagent. The nonpolar matrices used in this study are shown to be as equally effective as the conventional matrices. The uniform mixing of the nonpolar matrices and the nonpolar analytes enhances the MALDI-MS spectral reproducibility. Silver salts were found to be the best cationization reagents for all of the cases studied. Copper salts worked well for polystyrene, poorly for polyisoprene, and not at all for polybutadiene samples. These matrices should be useful for the characterization of hydrocarbon polymers and other analytes, such as modified polymers, which may potentially be sensitive to acidic matrices. (J Am Soc Mass Spectrom 2000, 11, 731-737) (C) 2000 American Society for Mass Spectrometry.
引用
收藏
页码:731 / 737
页数:7
相关论文
共 32 条
[1]   MASS-SPECTROMETRY OF SYNTHETIC-POLYMERS BY UV MATRIX-ASSISTED LASER DESORPTION IONIZATION [J].
BAHR, U ;
DEPPE, A ;
KARAS, M ;
HILLENKAMP, F ;
GIESSMANN, U .
ANALYTICAL CHEMISTRY, 1992, 64 (22) :2866-2869
[2]   Evaluation of matrix-assisted laser desorption ionization mass spectrometry for polymer characterization [J].
Belu, AM ;
DeSimone, JM ;
Linton, RW ;
Lange, GW ;
Friedman, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (01) :11-24
[3]  
CORNETT L, 1998, ASMS P 46 ASMS C MAS
[4]  
Cotton F., 1999, ADV INORGANIC CHEM
[5]   THE ANALYSIS OF WATER-SOLUBLE POLYMERS BY MATRIX-ASSISTED LASER DESORPTION TIME-OF-FLIGHT MASS-SPECTROMETRY [J].
DANIS, PO ;
KARR, DE ;
MAYER, F ;
HOLLE, A ;
WATSON, CH .
ORGANIC MASS SPECTROMETRY, 1992, 27 (07) :843-846
[6]  
Danis PO, 1996, RAPID COMMUN MASS SP, V10, P862
[7]   A FACILE SAMPLE PREPARATION FOR THE ANALYSIS OF SYNTHETIC ORGANIC POLYMERS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION [J].
DANIS, PO ;
KARR, DE .
ORGANIC MASS SPECTROMETRY, 1993, 28 (08) :923-925
[8]  
Deery MJ, 1997, RAPID COMMUN MASS SP, V11, P57, DOI 10.1002/(SICI)1097-0231(19970115)11:1<57::AID-RCM772>3.0.CO
[9]  
2-G
[10]   ROLE OF PHOTOIONIZATION AND PHOTOCHEMISTRY IN IONIZATION PROCESSES OF ORGANIC-MOLECULES AND RELEVANCE FOR MATRIX-ASSISTED LASER DESORPTION IONIZATION MASS-SPECTROMETRY [J].
EHRING, H ;
KARAS, M ;
HILLENKAMP, F .
ORGANIC MASS SPECTROMETRY, 1992, 27 (04) :472-480