APEX-SZ first light and instrument status

被引:49
作者
Dobbs, M.
Halverson, N. W. [1 ]
Ade, P. A. R.
Basu, K.
Beelen, A.
Bertoldi, F.
Cohalan, C.
Cho, H. M.
Guesten, R.
Holzapfel, W. L.
Kermish, Z.
Kneissl, R.
Kovacs, A.
Kreysa, E.
Lanting, T. M.
Lee, A. T.
Lueker, M.
Mehl, J.
Menten, K. M.
Muders, D.
Nord, M.
Plagge, T.
Richards, P. L.
Schilke, P.
Schwan, D.
Spieler, H.
Weiss, A.
White, M.
机构
[1] Univ Colorado, Boulder, CO 80309 USA
[2] Univ Bonn, Argelander Inst Astron, D-5300 Bonn, Germany
[3] Univ Calif Berkeley, Berkeley, CA 94720 USA
[4] Univ Cardiff Wales, Cardiff, Wales
[5] Lawrence Berkeley Natl Lab, Berkeley, CA USA
[6] Max Planck Inst Radioastron, D-5300 Bonn, Germany
[7] McGill Univ, Montreal, PQ, Canada
关键词
cosmology; observations; galaxies; clusters;
D O I
10.1016/j.newar.2006.09.029
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The APEX-sz instrument is designed for the discovery and study of galaxy clusters at mm-wavelengths using the Sunyaev Zel'dovich effect. The receiver consists of 320 superconducting transition edge sensor (TES) bolometers cooled to 250 mK with the combination of a three stage He sorption fridge and mechanical pulse tube cooler. The detectors are instrumented with a frequency domain multiplexing readout system. The receiver is mounted on the 12 m APEX telescope located at 5100 m on the Atacama plateau in Chile. For the first light engineering deployment of December 2005, the receiver was configured with a 55 element wedge of the bolometers and operating in the 150 GHz atmospheric window. During the engineering run we achieved significant milestones in our instrumentation development efforts, including celestial observations with a monolithically fabricated TES bolometer array cooled with a mechanical cooler and successful implementation of a SQUID-based MHz AC-biased readout. These technology demonstrations point the way toward future large TES bolometer array instruments. Here we describe the results of this deployment and future plans for the APEX-sz instrument. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:960 / 968
页数:9
相关论文
共 16 条
  • [1] APEX -: the Atacama Pathfinder EXperiment
    Guesten, R.
    Booth, R. S.
    Cesarsky, C.
    Menten, K. M.
    Agurto, C.
    Anciaux, M.
    Azagra, F.
    Belitsky, V.
    Belloche, A.
    Bergman, P.
    De Breuck, C.
    Comito, C.
    Dumke, M.
    Duran, C.
    Esch, W.
    Fluxa, J.
    Greve, A.
    Hafok, H.
    Haeupl, W.
    Helldner, L.
    Henseler, A.
    Heyminck, S.
    Johansson, L. E.
    Kasemann, C.
    Klein, B.
    Korn, A.
    Kreysa, E.
    Kurz, R.
    Lapkin, I.
    Leurini, S.
    Lis, D.
    Lundgren, A.
    Mac-Auliffe, F.
    Martinez, M.
    Melnick, J.
    Morris, D.
    Muders, D.
    Nyman, L. A.
    Olberg, M.
    Olivares, R.
    Pantaleev, M.
    Patel, N.
    Pausch, K.
    Philipp, S. D.
    Philipps, S.
    Sridharan, T. K.
    Polehampton, E.
    Reveret, V.
    Risacher, C.
    Roa, M.
    [J]. GROUND-BASED AND AIRBORNE TELESCOPES, PTS 1 AND 2, 2006, 6267
  • [2] The Atacama Pathfinder EXperiment (APEX) -: a new submillimeter facility for southern skies
    Guesten, R.
    Nyman, L. A.
    Schilke, P.
    Menten, K.
    Cesarsky, C.
    Booth, R.
    [J]. ASTRONOMY & ASTROPHYSICS, 2006, 454 (02) : L13 - L16
  • [3] DC SQUID series array amplifiers with 120 MHZ bandwidth (Corrected)
    Huber, ME
    Neil, PA
    Benson, RG
    Burns, DA
    Corey, AM
    Flynn, CS
    Kitaygorodskaya, Y
    Massihzadeh, O
    Martinis, JM
    Hilton, GC
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (02) : 4048 - 4053
  • [4] AN APPLICATION OF ELECTROTHERMAL FEEDBACK FOR HIGH-RESOLUTION CRYOGENIC PARTICLE-DETECTION
    IRWIN, KD
    [J]. APPLIED PHYSICS LETTERS, 1995, 66 (15) : 1998 - 2000
  • [5] The Atacama Cosmology Telescope
    Kosowsky, A
    [J]. NEW ASTRONOMY REVIEWS, 2003, 47 (11-12) : 939 - 943
  • [6] PHOTON NOISE IN PHOTOMETRIC INSTRUMENTS AT FAR-INFRARED AND SUBMILLIMETER WAVELENGTHS
    LAMARRE, JM
    [J]. APPLIED OPTICS, 1986, 25 (06): : 870 - 876
  • [7] Frequency domain multiplexing for bolometer arrays
    Lanting, TM
    Cho, HM
    Clarke, J
    Dobbs, M
    Lee, AT
    Lueker, M
    Richards, PL
    Smith, AD
    Spieler, HG
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3) : 548 - 550
  • [8] The impact of atmospheric fluctuations on degree-scale imaging of the cosmic microwave background
    Lay, OP
    Halverson, NW
    [J]. ASTROPHYSICAL JOURNAL, 2000, 543 (02) : 787 - 798
  • [9] Voltage-biased TES bolometers for the far-infrared to millimeter wavelength range
    Lee, AT
    Cho, S
    Gildemeister, J
    Halverson, N
    Holzapfel, W
    Mehr, J
    Myers, M
    Lanting, T
    Richards, P
    Rittweger, E
    Schwan, D
    Spieler, H
    Tran, H
    [J]. MILLIMETER AND SUBMILLIMETER DETECTORS FOR ASTRONOMY, 2003, 4855 : 129 - 135
  • [10] MARCUS C, 2003, ASTROPHYSICS J S, V149, P265