Damping evaluation using full-scale data of buildings in Japan

被引:270
作者
Satake, N
Suda, K
Arakawa, T
Sasaki, A
Tamura, Y
机构
[1] Shimizu Corp, Inst Technol, Koto Ku, Tokyo 1358530, Japan
[2] Sato Kogyo Co Ltd, Engn Res Inst, Atsugi, Kanagawa 2430211, Japan
[3] Meiji Univ, Sch Sci & Technol, Dept Architecture, Tama Ku, Kanagawa 2148571, Japan
[4] Nishimatsu Construct Co Ltd, Tech Res Inst, Aikawa, Kanagawa 2430303, Japan
[5] Tokyo Inst Polytech, Dept Architecture, Atsugi, Kanagawa 2430297, Japan
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 2003年 / 129卷 / 04期
关键词
damping; Japan; data analysis; databases; buildings;
D O I
10.1061/(ASCE)0733-9445(2003)129:4(470)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Full-scale data on damping of buildings in Japan have been collected by the Damping Evaluation Committee of the Architectural Institute of Japan. Reliable data on 137 steel-framed buildings, 25 reinforced concrete (RC) buildings, 43 steel-framed reinforced concrete (SRC) buildings have been compiled in a database. Most of these data have been evaluated from vibration tests in a small amplitude region. This paper describes damping ratio characteristics of steel-framed buildings and RC/SRC buildings based on analyses of the database, including effects of several building factors. It is shown that the higher the building, the smaller the first-mode damping ratio. Furthermore, the damping ratios seem to be affected by building use: Those of hotels and apartments are generally larger than those of other buildings. However, damping ratios are more widely scattered than natural periods, because they are also affected by vibration amplitude, foundation type, and so on. Frequency and amplitude dependencies of damping ratios are also examined, and predictors of damping ratios with their dependencies are proposed.
引用
收藏
页码:470 / 477
页数:8
相关论文
共 10 条
[1]  
*AIJ, 1978, VIBR TESTS BUILD STR
[2]  
AIJ-Architectural Institute of Japan, 2000, Damping in Buildings
[3]  
DAVENPORT AG, 1970, BWLT101970 U W ONT
[4]  
Davenport AG, 1986, Building motion in wind, P42
[5]   DAMPING IN TALL BUILDINGS - A MECHANISM AND A PREDICTOR [J].
JEARY, AP .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1986, 14 (05) :733-750
[6]   Damping in structures: Its evaluation and treatment of uncertainty [J].
Kareem, A ;
Gurley, K .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 59 (2-3) :131-157
[7]   FORECAST MODELS FOR DAMPING AND VIBRATION PERIODS OF BUILDINGS [J].
LAGOMARSINO, S .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1993, 48 (2-3) :221-239
[8]  
MAEBAYASHI K, 1989, P ANN M ARCH I JAP K, P381
[9]  
Sasaki A., 1998, P ANN M ARCH I JAP A, P379
[10]   Evaluation of amplitude-dependent damping and natural frequency of buildings during strong winds [J].
Tamura, Y ;
Suganuma, SY .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 59 (2-3) :115-130