Use of only a regular diagnostic His-bundle catheter for both fast and reproducible ''Para-Hisian pacing'' and stable right ventricular pacing

被引:19
作者
Heidbuchel, H
Ector, H
Adams, J
VandeWerf, F
机构
[1] Department of Cardiology, University Hospital Gasthuisberg, University of Leuven, Leuven
[2] Department of Cardiology, University Hospital Gasthuisberg, B-3000 Leuven
关键词
electrophysiology; pacing; conduction; atrioventricular node; accessory atrioventricular pathway;
D O I
10.1111/j.1540-8167.1997.tb00998.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pacing from the Diagnostic His-Bundle Catheter. Introduction: Para-Hisian pacing, i.e., pacing the anteroseptal right ventricle (RV) with or without direct capture of the His bundle (HB), allows the differentiation of VA conduction over the AV node from conduction over an accessory pathway. Classically, it is performed by maneuvering a separate pacing catheter around the HB catheter, which may be difficult and time-consuming. Methods and Results: This study prospectively evaluated the use of a single standard octapolar HB catheter with 2-mm interelectrode spacing for simultaneous (para-Hisian) pacing from the distal bipole and recording from the three proximal bipoles in 148 consecutive patients. Para-Hisian pacing was successful in 146 of 148 patients, performed within a median of only 10 seconds, and easily repeated several times during the course of tin electrophysiologic study. Retrograde HB activation could be recorded in 132 of 146 patients; a clearly different surface ECG configuration confirmed the presence or absence of HB capture in all other patients. Interestingly, stable RV pacing could be performed from the HB catheter for the rest of the electrophysiologic study in 138 of 142 patients in whom this was tried, RV pacing from this site also led to better interpretation of retrograde conduction, due to clear visualization of retrograde HB activation. Conclusion: Pacing from the distal bipole of a regular diagnostic HB catheter provides a fast and reliable way to perform para-Hisian pacing. Therefore, it may be advocated as a routine diagnostic protocol during electrophysiologic procedures. Moreover, pacing from this site obviates the need for a separate RV pacing catheter in most patients.
引用
收藏
页码:1121 / 1132
页数:12
相关论文
共 17 条
[1]   COEXISTENT MAHAIM AND KENT ACCESSORY CONNECTIONS - DIAGNOSTIC AND THERAPEUTIC IMPLICATIONS [J].
ABBOTT, JA ;
SCHEINMAN, MM ;
MORADY, F ;
SHEN, EN ;
MILLER, R ;
RUDER, MA ;
ELDAR, M ;
SEGER, JJ ;
DAVIS, JC ;
GRIFFIN, JC ;
DICARLO, LA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (02) :364-372
[2]  
ALDAY JDM, 1994, CIRCULATION, V89, P1060
[3]  
COUMEL P, 1974, European Journal of Cardiology, V1, P423
[4]  
ENGELSTEIN ED, 1993, CIRCULATION, V88, P295
[5]   ROLE OF MAHAIM FIBERS IN CARDIAC-ARRHYTHMIAS IN MAN [J].
GALLAGHER, JJ ;
SMITH, WM ;
KASELL, JH ;
BENSON, DW ;
STERBA, R ;
GRANT, AO .
CIRCULATION, 1981, 64 (01) :176-189
[6]   Para-Hisian pacing - A new method for differentiating retrograde conduction over an accessory AV pathway from conduction over the AV node [J].
Hirao, K ;
Otomo, K ;
Wang, XZ ;
Beckman, KJ ;
McClelland, JH ;
Widman, L ;
Gonzalez, MD ;
Arruda, M ;
Nakagawa, H ;
Lazzara, R ;
Jackman, WM .
CIRCULATION, 1996, 94 (05) :1027-1035
[7]   EFFECT OF CLASS IA ANTIARRHYTHMIC AGENTS ON FASCICULOVENTRICULAR FIBERS [J].
ITO, M ;
ONODERA, S ;
NOSHIRO, H ;
ODAKURA, H ;
YASUDA, S ;
NAGASHIMA, M ;
SHINODA, S ;
SUZUKI, H .
JOURNAL OF ELECTROCARDIOLOGY, 1990, 23 (04) :323-329
[8]  
JACKMAN WM, 1991, PACE, V14, P670
[9]  
Josephson M., 1993, Clinical cardiac electrophysiology, P311
[10]  
MILES WM, 1995, CARDIAC ELECTROPHYSI, P638