The effect of image distortion on 3-D reconstruction of coronary bypass grafts from angiographic views

被引:6
作者
Dorsaz, PA [1 ]
Dorsaz, L [1 ]
Doriot, PA [1 ]
机构
[1] Univ Hosp Geneva, Ctr Cardiol, CH-1211 Geneva, Switzerland
关键词
bypass grafts; image distortion; three-dimensional reconstruction;
D O I
10.1109/42.875203
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Three-dimensional (3-D) reconstructions of coronary bypass grafts performed from X-ray angiographic images may become increasingly important for the investigation of damaging mechanical stresses imposed to these vessels by the cyclic movement of the heart. Contrary to what we had experienced with coronary arteries, appreciable reconstruction artifacts frequently occur with grafts. In order to verify the hypothesis that those are caused by distortions present in the angiographic images (acquired with image intensifiers), we have implemented a grid correction technique in our 3-D reconstruction method and studied its efficiency with phantom experiments. In this article, the nature of the encountered artifacts and the may in which the dewarping correction eliminates them are illustrated by a phantom experiment and by the reconstruction of a real coronary bypass vein graft.
引用
收藏
页码:759 / 762
页数:4
相关论文
共 9 条
[1]   ANALYSIS AND CORRECTION OF IMPERFECTIONS IN THE IMAGE INTENSIFIER-TV-DIGITIZER IMAGING CHAIN [J].
BOONE, JM ;
SEIBERT, JA ;
BARRETT, WA ;
BLOOD, EA .
MEDICAL PHYSICS, 1991, 18 (02) :236-242
[2]   IMAGE INTENSIFIER DISTORTION CORRECTION [J].
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1987, 14 (02) :249-252
[3]   CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS [J].
CHO, PS ;
JOHNSON, RH ;
GRIFFIN, TW .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11) :1863-1883
[4]   Assessment of image intensifier and distortion for DSA localization studies [J].
Coste, E ;
Gibon, D ;
Rousseau, J .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 :70-73
[5]   The accuracy and reproducibility of a global method to correct for geometric image distortion in the x-ray imaging chain [J].
Gronenschild, E .
MEDICAL PHYSICS, 1997, 24 (12) :1875-1888
[6]   SPATIAL RECONSTRUCTION OF CORONARY-ARTERIES FROM ANGIOGRAPHIC IMAGES [J].
GUGGENHEIM, N ;
DORIOT, PA ;
DORSAZ, PA ;
DESCOUTS, P ;
RUTISHAUSER, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (01) :99-110
[7]   Aortocoronary saphenous vein graft disease - Pathogenesis, predisposition, and prevention [J].
Motwani, JG ;
Topol, EJ .
CIRCULATION, 1998, 97 (09) :916-931
[8]   ACCURATE CHARACTERIZATION OF IMAGE INTENSIFIER DISTORTION [J].
RUDIN, S ;
BEDNAREK, DR ;
WONG, R .
MEDICAL PHYSICS, 1991, 18 (06) :1145-1151
[9]   AUTOMATED AND ACCURATE ASSESSMENT OF THE DISTRIBUTION, MAGNITUDE, AND DIRECTION OF PINCUSHION DISTORTION IN ANGIOGRAPHIC IMAGES [J].
VANDERZWET, PMJ ;
MEYER, DJH ;
REIBER, JHC .
INVESTIGATIVE RADIOLOGY, 1995, 30 (04) :204-213