Porous - Si based bio reactors for glucose monitoring.

被引:3
作者
Fichera, M [1 ]
Libertino, S [1 ]
D'Arrigo, G [1 ]
机构
[1] CNR, IMM, I-95121 Catania, Italy
来源
BIOENGINEERED AND BIOINSPIRED SYSTEMS | 2003年 / 5119卷
关键词
D O I
10.1117/12.501338
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Biosensors are a very useful tool to produce drugs or to monitor chemical species through their product of reaction. The sensor is fabricated bounding on its surface specific enzymes that can accomplish the synthesis function. We studied the possibility to fabricate Si-based micro-biosensors to detect glucose in water solutions using porous Si (PS) as surface to bound the specific enzyme. We ideated and fabricated a novel biosensor structure based on a PS membrane that can be used for glucose monitoring and for drug production, by properly choosing the enzyme to immobilize in the reactor. The fabrication details of the structure, having a suspended and auto-supporting PS membrane, through surface micromachining processes, ULSI compatible, are shown. Micro channels localised below the membrane will allow the buffer solution flow through the porous matrix. Moreover, in this work we acquired the know-how on the enzyme manipulation, bonding and detection on Si-based surfaces. The enzyme that accomplish the synthesis function is the glucose oxidase. We deposited it on different substrates: PS, bulk Si and on glass. On these samples photoluminescence, absorbance and optical microscopy measurements were performed.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 13 条
[1]  
[Anonymous], MAT TODAY JAN
[2]   Improved performance in silicon enzyme microreactors obtained by homogeneous porous silicon carrier matrix [J].
Bengtsson, M ;
Ekström, S ;
Marko-Varga, G ;
Laurell, T .
TALANTA, 2002, 56 (02) :341-353
[3]  
Bengtsson M, 2000, PHYS STATUS SOLIDI A, V182, P495, DOI 10.1002/1521-396X(200011)182:1<495::AID-PSSA495>3.0.CO
[4]  
2-4
[5]   Microfabricated devices in biotechnology and biochemical processing [J].
Chován, T ;
Guttman, A .
TRENDS IN BIOTECHNOLOGY, 2002, 20 (03) :116-122
[6]   The fluorescence emission of the apo-glucose oxidase from Aspergillus niger as probe to estimate glucose concentrations [J].
D'Auria, S ;
Herman, P ;
Rossi, M ;
Lakowicz, JR .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1999, 263 (02) :550-553
[7]  
DARRIGO G, MAT SCI ENG C, V23, P13
[8]   Porous silicon as the carrier matrix in microstructured enzyme reactors yielding high enzyme activities [J].
Drott, J ;
Lindstrom, K ;
Rosengren, L ;
Laurell, T .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (01) :14-23
[9]  
DROTT J, 1998, THIN SOLID FILMS, P330
[10]   Evaluation of MEMS materials of construction for implantable medical devices [J].
Kotzar, G ;
Freas, M ;
Abel, P ;
Fleischman, A ;
Roy, S ;
Zorman, C ;
Moran, JM ;
Melzak, J .
BIOMATERIALS, 2002, 23 (13) :2737-2750