AP diameter shows the strongest correlation with CTDI and DLP in abdominal and chest CT

被引:32
作者
Zarb, Francis [1 ]
Rainford, Louise [2 ]
McEntee, Mark F. [2 ]
机构
[1] Univ Malta, Inst Hlth Care, Msida, Malta
[2] Hlth Sci Ctr, Sch Med & Med Sci, Dublin 4, Ireland
关键词
AUTOMATIC EXPOSURE CONTROL; COMPUTED-TOMOGRAPHY; PATIENT SIZE; TUBE CURRENT; DOSE REDUCTION; MODULATION;
D O I
10.1093/rpd/ncq115
中图分类号
X [环境科学、安全科学];
学科分类号
083001 [环境科学];
摘要
The purpose of this study is to investigate the relationships among cross-sectional diameters, weight and computed tomography (CT) dose descriptors (CTDI and DLP) to identify which is best used as a measure for the establishment of DRLs in CT. Data (gender, weight, cross-sectional diameters, dose descriptors) from 56 adult patients attending for either a CT examination of the abdomen or chest was obtained from two spiral CT units using automatic milliampere modulation. The AP diameter was demonstrated as the main contributing factor influencing the dose in CT (CTDI: r(2) = 0.269, p-value < 0.001; DLP: r(2) = 0.260, p-value < 0.001) since it has a greater correlation with radiation dose than body weight and can thus be its substitute in dose-reduction strategies and establishment of DRLs. The advantages of using the AP diameter are that it can easily be measured prior to scanning or retrospectively from previous CT images. However, further studies on the practicality of this approach are recommended.
引用
收藏
页码:266 / 273
页数:8
相关论文
共 29 条
[1]
Aldrich JE, 2006, CAN ASSOC RADIOL J, V57, P152
[2]
Classifying preadolescent boys based on their weight status and percent body fat produces different groups [J].
Brann, Lynn S. .
JOURNAL OF THE AMERICAN DIETETIC ASSOCIATION, 2008, 108 (06) :1018-1022
[3]
Bruesewitz M., 2008, Smart mA automatic exposure control (AEC)
[4]
Bryman A., 2001, QUANTITATIVE DATA AN
[5]
Daly LE., 2000, Interpretation and Uses of Medical Statistics, V5th
[6]
Use of automatic exposure control in multislice computed tomography of the coronaries:: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography [J].
Deetjen, Anja ;
Moellmann, Susanne ;
Conradi, Guido ;
Rolf, Andreas ;
Schmermund, Axel ;
Hamm, Christian W. ;
Dill, Thorsten .
HEART, 2007, 93 (09) :1040-1043
[7]
Directorate-General Environment Nuclear Safety and Civil Protection European Commission, 1999, RAD PROT 109 GUID DI
[8]
Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[9]
HAAGA J, 2001, AJR, P289
[10]
Image quality and dose in computed tomography [J].
Jurik, AG ;
Jessen, KA ;
Hansen, J .
EUROPEAN RADIOLOGY, 1997, 7 (01) :77-81