A TEM study of two water-based adhesive systems bonded to dry and wet dentin

被引:229
作者
Van Meerbeek, B
Yoshida, Y
Lambrechts, P
Vanherle, G
Duke, ES
Eick, JD
Robinson, SJ
机构
[1] Catholic Univ Louvain, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Operat Dent & Dent Mat, BIOMAT, B-3000 Louvain, Belgium
[2] Hiroshima Univ, Sch Dent, Dept Dent Mat, Hiroshima, Japan
[3] Univ Texas, Hlth Sci Ctr, Sch Dent, Clin Res Facil, San Antonio, TX 78284 USA
[4] Univ Missouri, Sch Dent, Dept Oral Biol, Kansas City, MO 64110 USA
关键词
bonding; dentin; resin-dentin interfaces; collagen; TEM;
D O I
10.1177/00220345980770010501
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To keep the exposed collagen scaffold penetrable to resin, it has been recommended that the conditioned dentin surface be maintained in a visibly moist condition, a clinical technique commonly referred to as wet bonding. In this study, resin-dentin interfaces produced with two waterbased adhesive systems-OptiBond (OPTI, Kerr) and Scotchbond Multi-Purpose (SBMP, 3M)-were compared by transmission electron microscopy, following the application of either a dry-or a wet-bonding technique. The hypothesis advanced was that the ultramorphology of the hybrid layer would differ depending on which bonding method was applied. A morphologically well-organized hybrid layer of collagen fibrils intermingled with resin in tiny interfibrillar channels was consistently formed by the OPTI system. The SBMP system was found to produce a hybrid layer with a more variable ultrastructure, less distinctly outlined collagen fibrils, and a characteristic electron-dense phase located at its surface. No major differences in hybrid layer ultrastructure were observed when the two adhesive systems investigated were bonded to either dry or wet dentin. When the adhesives were dry-bonded, no ultrastructural evidence of collapsed demineralized collagen, incompletely or not at all infiltrated by resin, could be detected. In addition, when the two adhesives were bonded to wet dentin, no signs of overwetting phenomena, that would have indicated that water was ineffectively removed, were apparent. It has been hypothesized that the amount of water provided with the hydrophilic primer solution of either of the two adhesive systems investigated suffices to re-hydrate and re-expand the gently air-dried and collapsed collagen network. Further research should be directed to determine whether this hypothesized self-rewetting effect can be extrapolated to other adhesive systems that provide water-based primers.
引用
收藏
页码:50 / 59
页数:10
相关论文
共 30 条
[1]  
BAYNE SC, 1994, T ACAD DENT MAT, V7, P91
[2]  
CHARLTON DG, 1994, OPER DENT, V19, P154
[3]   THE EXTENT AND DISTRIBUTION OF INTRATUBULAR COLLAGEN FIBRILS IN HUMAN DENTIN [J].
DAI, XF ;
TENCATE, AR ;
LIMEBACK, H .
ARCHIVES OF ORAL BIOLOGY, 1991, 36 (10) :775-778
[4]  
Finger WJ, 1996, AM J DENT, V9, P27
[5]  
Gwinnett A J, 1994, Am J Dent, V7, P144
[6]  
Gwinnett A J, 1992, Am J Dent, V5, P127
[7]  
Inokoshi S, 1990, JPN J CONSERV DENT, V33, P427
[8]   SOME EFFECTS OF WATER ON DENTIN BONDING [J].
JACOBSEN, T ;
SODERHOLM, KJ .
DENTAL MATERIALS, 1995, 11 (02) :132-136
[9]   IMPROVING BOND STRENGTH THROUGH ACID ETCHING OF DENTIN AND BONDING TO WET DENTIN SURFACES [J].
KANCA, J .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1992, 123 (09) :35-43
[10]  
Kanca J 3rd, 1992, Quintessence Int, V23, P39