Feasibility of image registration and intensity-modulated radiotherapy planning with hyperpolarized helium-3 magnetic resonance imaging for non-small-cell lung cancer

被引:97
作者
Ireland, Rob H. [1 ]
Bragg, Chris M.
McJury, Mark
Woodhouse, Neil
Fichele, Stan
Van Beek, Edwin J. R.
Wild, Jim M.
Hatton, Matthew Q.
机构
[1] Univ Sheffield, Acad Unit Radiol, Sheffield S10 2JF, S Yorkshire, England
[2] Univ Sheffield, Acad Unit Med Phys, Sheffield S10 2JF, S Yorkshire, England
[3] Univ Sheffield, Acad Unit Clin Oncol, Sheffield S10 2JF, S Yorkshire, England
[4] Weston Pk Hosp, Dept Radiotherapy, Sheffield, S Yorkshire, England
[5] Belfast City Hosp Trust, Dept Med Phys, Belfast, Antrim, North Ireland
[6] Univ Iowa, Carver Coll Med, Dept Radiol, Iowa City, IA 52242 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2007年 / 68卷 / 01期
基金
英国工程与自然科学研究理事会;
关键词
hyperpolarized helium-3 MRI; image registration; IMRT treatment planning; non-small-cell lung cancer;
D O I
10.1016/j.ijrobp.2006.12.068
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Purpose: To demonstrate the feasibility of registering hyperpolarized helium-3 magnetic resonance images (He-3-MRI) to X-ray computed tomography (CT) for functionally weighted intensity-modulated radiotherapy (IMRT) planning. Methods and Materials: Six patients with non-small-cell lung cancer underwent He-3 ventilation MRI, which was fused with radiotherapy planning CT using rigid registration. Registration accuracy was assessed using an overlap coefficient, calculated as the proportion of the segmented He-3-MR volume (V-MRI) that intersects the segmented CT lung volume expressed as a percentage of V-MRI. For each patient, an IMRT plan that minimized the volume of total lung receiving a dose >= 20 Gy (V-20) was compared with a plan that minimized the V-20, to well-ventilated lung defined by the registered He-3-MRI. Results: The He-3-MRI and CT were registered with sufficient accuracy to enable functionally guided IMRT planning (median overlap, 89%; range, 72-97%). In comparison with the total lung IMRT plans, IMRT constrained with He-3-MRI reduced the V-20, not only for the well-ventilated lung (median reduction, 3.1%; range, 0.4-5.1%; p = 0.028) but also for the total lung volume (median reduction, 1.6%; range, 0.2-3.7%; p = 0.028). Conclusions: Statistically significant improvements to IMRT plans are possible using functional information provided by He-3-MRI that has been registered to radiotherapy planning CT. (c) 2007 Elsevier Inc.
引用
收藏
页码:273 / 281
页数:9
相关论文
共 26 条
[1]
Efficient nonlinear registration of 3D images using high order co-ordinate transfer functions [J].
Barber, DC .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1999, 23 (05) :157-168
[2]
The role of intensity-modulated radiotherapy in the treatment of parotid tumors [J].
Bragg, CM ;
Conway, J ;
Robinson, MH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (03) :729-738
[3]
The incorporation of SPECT functional lung imaging into inverse radiotherapy planning for non-small cell lung cancer [J].
Christian, JA ;
Partridge, M ;
Nioutsikou, E ;
Cook, G ;
McNair, HA ;
Cronin, B ;
Courbon, F ;
Bedford, JL ;
Brada, M .
RADIOTHERAPY AND ONCOLOGY, 2005, 77 (03) :271-277
[4]
Feasibility of optimizing the dose distribution in lung tumors using fluorine-18-fluorodeoxyglucose positron emission tomography and single photon emission computed tomography guided dose prescriptions [J].
Das, SK ;
Miften, MM ;
Zhou, S ;
Bell, M ;
Munley, MT ;
Whiddon, CS ;
Craciunescu, O ;
Baydush, AH ;
Wong, T ;
Rosenman, JG ;
Dewhirst, MW ;
Marks, LB .
MEDICAL PHYSICS, 2004, 31 (06) :1452-1461
[5]
Feasibility of combining MR perfusion, angiography, and 3He ventilation imaging for evaluation of lung function in a porcine model [J].
Hong, C ;
Leawoods, JC ;
Yablonskiy, DA ;
Leyendecker, JR ;
Bae, KT ;
Pilgram, TK ;
Woodard, PK ;
Conradi, MS ;
Zheng, J .
ACADEMIC RADIOLOGY, 2005, 12 (02) :202-209
[6]
IRELAND RH, 2004, NUCL MED COMMUN, V25, P318
[7]
Quantification of radiation-induced regional lung injury with perfusion imaging [J].
Marks, LB ;
Munley, MT ;
Spencer, DP ;
Sherouse, GW ;
Bentel, GC ;
Hoppenworth, J ;
Chew, M ;
Jaszczak, RJ ;
Coleman, RE ;
Prosnitz, LR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (02) :399-409
[8]
THE UTILITY OF SPECT LUNG PERFUSION SCANS IN MINIMIZING AND ASSESSING THE PHYSIOLOGICAL CONSEQUENCES OF THORACIC IRRADIATION [J].
MARKS, LB ;
SPENCER, DP ;
BENTEL, GC ;
RAY, SK ;
SHEROUSE, GW ;
SONTAG, MR ;
COLEMAN, RE ;
JASZCZAK, RJ ;
TURKINGTON, TG ;
TAPSON, V ;
PROSNITZ, LR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (04) :659-668
[9]
Incorporation of functional status into dose-volume analysis [J].
Marks, LB ;
Sherouse, GW ;
Munley, MT ;
Bentel, GC ;
Spencer, DP .
MEDICAL PHYSICS, 1999, 26 (02) :196-199
[10]
Incorporation of functional imaging data in the evaluation of dose distributions using the generalized concept of equivalent uniform dose [J].
Miften, MM ;
Das, SK ;
Su, M ;
Marks, LB .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (09) :1711-1721