Immunogold-silver staining-on-a-chip biosensor based on cross-flow chromatography's

被引:51
作者
Cho, Il-Hoon [1 ]
Seo, Sung-Min [1 ]
Paek, Eui-Hwan [2 ]
Paek, Se-Hwan [1 ,2 ,3 ]
机构
[1] Korea Univ, Program Biomicrosyst Technol, Seoul 136701, South Korea
[2] Korea Univ, BioDigit Labs Corp, Technol Incubat Ctr, Seoul 136701, South Korea
[3] Korea Univ, Dept Biotechnol & Bioinformat, Jochiwon 339800, Choongnam, South Korea
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 02期
关键词
Silver intensification; Non-laboratory immunoassay; Background staining control; Self-nucleation ions; Detection capability; Cardiac troponin I; NANOPARTICLE; ENHANCEMENT; ANTIBODIES; ASSAYS;
D O I
10.1016/j.jchromb.2009.07.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Immunogold-silver staining (IGSS) was adopted in cross-flow chromatographic analysis in which immunological reactions and silver intensification were sequentially conducted in the vertical and horizontal directions, respectively Factors controlling the performance. except the silver substrate solution. were optimized to increase the signal-to-background ratio in measurements of cardiac troponin I as a model analyte In generating the signal, the size of colloidal gold catalyst was critical. the smallest size (5-nm diameter) in the selected range yielded the highest colorimeric signal. To maintain the low background, two processes, blocking the remaining surfaces of membrane after antibody immobilization and washing the residual tracer after immunological reaction, were necessary. Self-nucleation of silver ions also caused a background signal and was controlled to some degree by decreasing the hydrodynamic force that arose when the substrate solution was supplied in the horizontal direction finally, a new chip (IGSS-on-a-chip, IOC) that allowed for convenient, efficient IGSS was produced by injection molding of plastic This method enhanced the detection capability by 51-fold compared to the conventional rapid test kit using 30 nm-sized colloidal gold as the tracer. The IOC biosensor results also showed that silver intensification yield via cross flow after Immunological reaction was 19% higher than that by traditional incubation. (C) 2009 Elsevier B.V All rights reserved
引用
收藏
页码:271 / 277
页数:7
相关论文
共 27 条
[1]   Colloidal gold-based immunochromatogrphic assay for detection of botulinum neurotoxin type B [J].
Chiao, DJ ;
Shyu, RH ;
Hu, CS ;
Chiang, HY ;
Tang, SS .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01) :37-41
[2]   Site-directed biotinylation of antibodies for controlled immobilization of solid surfaces [J].
Cho, Il-Hoon ;
Paek, Eui-Hwan ;
Lee, Haiwort ;
Kang, Ji Yoon ;
Kim, Tae Song ;
Paek, Se-Hwan .
ANALYTICAL BIOCHEMISTRY, 2007, 365 (01) :14-23
[3]   Plastic ELISA-on-a-chip based on sequential cross-flow chromatography [J].
Cho, JH ;
Han, SM ;
Paek, EH ;
Cho, IH ;
Paek, SH .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :793-800
[4]   An enzyme immunoanalytical system based on sequential cross-flow chromatography [J].
Cho, JH ;
Paek, EH ;
Cho, IH ;
Paek, SH .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4091-4097
[5]   Pre-hospital detection of acute myocardial infarction with ultra-rapid human fatty acid-binding protein (H-FABP) immunoassay [J].
Ecollan, Patrick ;
Collet, Jean-Philippe ;
Boon, Guillaume ;
Tanguy, Marie-Laure ;
Fievet, Marie-Laurence ;
Haas, Rosita ;
Bertho, Nicolas ;
Siami, Shidash ;
Hubert, Jean-Christophe ;
Coriat, Pierre ;
Montalescot, Gilles .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 119 (03) :349-354
[6]   Single particle studies of the autocatalytic metal deposition onto surface-bound gold nanoparticles reveal a linear growth [J].
Festag, Grit ;
Steinbrueck, Andrea ;
Csaki, Andrea ;
Moeller, Robert ;
Fritzsche, Wolfgang .
NANOTECHNOLOGY, 2007, 18 (01)
[7]   PRODUCTION OF ANTIBODIES OF IDENTICAL IDIOTYPE BUT DIVERSE IMMUNOGLOBULIN CLASSES BY CELLS DERIVED FROM A SINGLE STIMULATED B CELL [J].
GEARHART, PJ ;
SIGAL, NH ;
KLINMAN, NR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1975, 72 (05) :1707-1711
[8]  
Hacker Gerhard W., 1996, Methods (Orlando), V10, P257, DOI 10.1006/meth.1996.0100
[9]   High sensitivity immunoassays using particulate fluorescent labels [J].
Hall, M ;
Kazakova, I ;
Yao, YM .
ANALYTICAL BIOCHEMISTRY, 1999, 272 (02) :165-170
[10]   Plastic enzyme-linked immunosorbent assays (ELISA)-on-a-chip biosensor for botulinum neurotoxin A [J].
Han, Seung-Mok ;
Cho, Joung-Hwan ;
Cho, Il-Hoon ;
Paek, Eui-Hwan ;
Oh, Hee-Bok ;
Kim, Bong-Su ;
Ryu, Chunsun ;
Lee, Kyunghee ;
Kim, Young-Kee ;
Paek, Se-Hwan .
ANALYTICA CHIMICA ACTA, 2007, 587 (01) :1-8