The effects of experimental tear film removal on corneal surface regularity and barrier function

被引:43
作者
Dursun, D
Monroy, D
Knighton, R
Tervo, T
Vesaluoma, M
Carraway, K
Feuer, W
Pflugfelder, SC
机构
[1] Univ Miami, Sch Med, Bascom Palmer Eye Inst, Ocular Surface & Tear Ctr, Miami, FL 33136 USA
[2] Univ Helsinki, Hosp Eye, Helsinki, Finland
[3] Univ Miami, Sch Med, Dept Anat & Cell Biol, Miami, FL 33136 USA
[4] Univ Miami, Sch Med, Dept Biostat, Miami, FL 33136 USA
关键词
D O I
10.1016/S0161-6420(00)00273-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate corneal surface regularity and asymmetry, corneal thickness, barrier function, and contrast sensitivity after experimental removal of the precorneal tear layer. Design: Prospective, clinic-based, nonrandomized (self-controlled) comparative trial. Participants: Six eyes of six healthy volunteers (three males, three females; age range, 29-40 years). Methods: A precorneal tear lesion was created by pressing a sterile Biopore (Millipore, Bedford, MA) Teflon membrane against the central cornea. Corneal topography with both the Topographic Modeling System (TMS-1; Computed Anatomy, Tomey Technology, Cambridge, MA) and the Orbscan (Orbscan Inc., Salt Lake City, UT) were performed before the lesion was created and 30 seconds, 1 hour, and 4 hours after the lesion was created. Surface regularity and surface asymmetry indices were evaluated by the TMS-1 topography system. Maximum and minimum keratometric readings, corneal fluorescein staining, contrast sensitivity, and corneal thickness were evaluated before and after the tear lesion. Cytologic membranes were stained for MUC4 mucin using an indirect immunofluorescent staining technique. Confocal microscopy was performed to evaluate the integrity of the corneal epithelium in two eyes. Analysis of variance with polynomial contrasts was used to examine time trends of the outcome variables. Main Outcome Measures: The change in corneal surface regularity and asymmetry indices, corneal thickness, permeability to fluorescein dye, and contrast sensitivity before and after the lesion was made were compared. Results: The corneal epithelium in the area of the lesion showed intense fluorescein staining 30 seconds postlesion but appeared normal by 4 hours. Confluent, homogeneous staining for MUC4 mucin was observed on the membranes used to create the lesion in all cases. The surface regularity index measured with the TMS-1 increased after the lesion was created and decreased toward normal by 4 hours (P = 0.017). Corneal thickness measured by the Orbscan instrument significantly increased in the central (P = 0.001), superior (P = 0.006), inferotemporal (P < 0.001) and superotemporal (P = 0.001) cornea immediately following the lesion and returned to normal by 4 hours. The lesion caused a decrease in visual acuity at 6.30%, 4% and 2.5% contrast sensitivities 1 hour postlesion and these measurements returned to prelesion values by 4 hours (P = 0.085, P = 0.005, P = 0.043). Conclusions: The precorneal tear layer serves as a permeability barrier and is essential for maintaining a smooth quality optical surface. Ophthalmology 2000;107:1754-1760 (C) 2000 by the American Academy of Ophthalmology.
引用
收藏
页码:1754 / 1760
页数:7
相关论文
共 28 条
[1]   Correlation of tear fluorescein clearance and Schirmer test scores with ocular irritation symptoms [J].
Afonso, AA ;
Monroy, D ;
Stern, ME ;
Feuer, WJ ;
Tseng, SCG ;
Pflugfelder, SC .
OPHTHALMOLOGY, 1999, 106 (04) :803-810
[2]  
Afonso AA, 1999, INVEST OPHTH VIS SCI, V40, P2506
[3]  
Chen HB, 1997, INVEST OPHTH VIS SCI, V38, P381
[4]  
Danjo Y, 1998, INVEST OPHTH VIS SCI, V39, P2602
[6]  
Dingeldein S A, 1989, Refract Corneal Surg, V5, P372
[7]  
FLUGFELDER SC, 2000, INVEST OPHTH VIS SCI, V41, P1316
[8]   Mucin genes expressed by the ocular surface epithelium [J].
Gipson, IK ;
Inatomi, T .
PROGRESS IN RETINAL AND EYE RESEARCH, 1997, 16 (01) :81-98
[9]  
GOBBELS M, 1992, OPHTHALMOLOGY, V99, P873
[10]  
GREINER JV, 1985, ACTA OPHTHALMOL, V63, P89