Comparison of on-line single-capillary and bridge capillary viscometric detectors for size exclusion chromatography

被引:44
作者
Norwood, DP [1 ]
Reed, WF [1 ]
机构
[1] Tulane Univ, Dept Phys, New Orleans, LA 70118 USA
基金
美国国家科学基金会;
关键词
size exclusion chromatography; viscometry; light scattering;
D O I
10.1080/10236669708033941
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
A systematic and thorough comparison is made of a laboratory-built single-capillary viscometer and a bridge viscometer, integrated together into a size exclusion chromatography (SEC) apparatus incorporating a multi-angle laser light scattering (MALLS) photometer and a differential refractometer. It is demonstrated that proper choice of the SEC pump is crucial to realize the potential accuracy of either viscometer design. Random measurement error contributes an order of magnitude greater error in the single-capillary viscometer than in the bridge viscometer, and thus the bridge viscometer gives significantly greater precision in any one measurement. Other sources of error, such as calibration error and stochastic variation from one run to the next, however, reduce the bridge viscometer's greater precision to only about a factor of two greater than the single-capillary design. Two advantages compensating for the laboratory-built single-capillary viscometer's decreased precision are its compactness and its significantly lower cost. By the use of variety of polymers (hyaluronate, poly(vinyl pyrrolidone) and dextran), estimates of scaling laws for both soot-mean-square radius of gyration and reduced viscosity are made, and their accuracies and sources of error assessed.
引用
收藏
页码:99 / 132
页数:34
相关论文
共 37 条
[1]  
[Anonymous], 1994, TRENDS POLYM SCI
[2]   UNIVERSAL CALIBRATION ASSESSMENT IN AQUEOUS GEL-PERMEATION CHROMATOGRAPHY [J].
BAHARY, WS ;
JILANI, M .
JOURNAL OF APPLIED POLYMER SCIENCE, 1993, 48 (09) :1531-1538
[3]   DETERMINATION OF SCALING PROPERTIES OF RANDOMLY BRANCHED POLYCYANURATES BY COMBINED SEC/LALLS/VISC [J].
BAUER, J ;
BURCHARD, W .
MACROMOLECULES, 1993, 26 (12) :3103-3107
[4]   THE APPLICATION OF FIELD-FLOW FRACTIONATION TECHNIQUES TO THE CHARACTERIZATION OF COMPLEX ENVIRONMENTAL-SAMPLES [J].
BECKETT, R .
ENVIRONMENTAL TECHNOLOGY LETTERS, 1987, 8 (07) :339-354
[5]  
BENOIT H, 1966, J CHIM PHYS PHYS CHI, V63, P1506
[6]  
BRANDRUP J, 1989, POLYMER HDB
[7]  
CALDWELL KD, 1988, ANAL CHEM, V60, P959
[8]  
De Gennes P.-G., 1979, SCALING CONCEPTS POL
[9]   THE INTRINSIC VISCOSITY OF POLYMER SOLUTIONS [J].
DEBYE, P .
JOURNAL OF CHEMICAL PHYSICS, 1946, 14 (10) :636-639
[10]   THE DETERMINATION OF PARTICLE-SIZE DISTRIBUTION OF SUBMICROMETER PARTICLES BY CAPILLARY HYDRODYNAMIC FRACTIONATION (CHDF) [J].
DOSRAMOS, JG ;
SILEBI, CA .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1990, 135 (01) :165-177